Operation

Risk of death when operating the water treatment system during bathing.
Hair or clothing might get sucked into the suction openings of the pool and in extreme cases
trap persons under water and prevent them from surfacing again.
- Never operate water treatment system devices while persons are in the pool.
- Prevent any access to the pool for as long as water treatment system devices are in use.
A damaged device or damaged accessories may cause injuries.
- Check the device and the accessories (see section "Testing").
Reduced or blocked ventilation of the heat pump can lead to faulty extraction of heat or
moisture. This might cause mold or overheating of the finned heat exchanger.
- Clean the grate in front of the fan impeller and the fins of the heat exchanger at regular
intervals and make sure that dirt such as leaves or similar does not get into the heat
exchanger.
- Make sure that the grate on the heat exchanger is never covered up and that the air can
circulate freely through the device.

RCD power plug

The RCD power plug consists of a safety plug and
a residual current circuit breaker. The safety plug
must be connected to a matching socket with an
earthed protective conductor. The residual current
circuit breaker disconnects the heat pump from the
voltage as soon as unexpectedly high currents that
are dangerous for persons flow through the heat
pump (e.g. short circuit through electroconductive
parts of the housing).
Testing the residual current circuit breaker
1. Connect the RCD power plug to the power
supply prepared at the setup location.
2. Press the RESET button.
The (POWER) LED is lit. The heat pump is
supplied with power and is in standby mode.
3. Press the TEST button.
The (POWER) LED goes off. The heat pump is disconnected from the power.
4. Press the RESET button.
The (POWER) LED is lit. The heat pump is supplied with power and is in standby mode.
The residual current circuit breaker of the RCD power plug has been tested successfully.

Activating heating

The adjustable temperature range in heating operating mode is 5 – 45 °C. However, the set water
temperature must not differ by more than 15 °C from the ambient temperature; otherwise an error
42
WARNING!
CAUTION!
Risk of injury!
NOTICE!
J
POWER
RESET
TEST