4. Push all connected wires up into junction box.
5. Reinstall the canopy on the haanger bracket.
6. Carefully tuck the wire connections inside the outlet box. Use the
screws provided to secure the wall control to the wall outlet box and
push wall plate to the wall control. (Fig. 3)
2. OPERATING THE WALL CONTROL (Fig. 4 & 5):
Fan control "
" and " " bottons:
Press and hold the "
" Fans speed button for Fan ON/OFF.
Pressing and releasing the" " button one time will increase the
speed of the fan. Pressing and holding the" " button for more than
1 second to begin adjusting the fan speeds from Low to High cycle
and the increments will be denoted on the indicator LED. If the fan
is OFF, the fan speed indicator LEDs will also be off. Fan control
with automatic speed memory.
= Low Speed
= MED. Speed
= MED. Hi Speed
= Hi Speed
The "
" button: Controls fan direction.
Light control "
" and "
For fans that use LED bulbs, select "D" in the dip switch (Fig. 5),
The "
" button turns the light ON or OFF. Pressing and holding
the"
" button to set the desired brightness. The light button has an
auto-resume; it will stay at the same brightness as the last time it
was turned off. Select "O" in the dip switch, this button will control
the light ON/OFF only.
OFF-ON Slide Button-This button turns the power Off and On to
the Fan and Light(s).
NOTE: A single wall control can be controlled with as many as 3
fans in one room. (The light wattage should not exceed 150W.)
YOUR WALL NOW HAS FULL CONTROL OF THE FAN
AND LIGHT.
3. TROUBLE SHOOTING
1. Fails to operate:
a. Power to fan?
b. Fan wired correctly?
c. Light kit switch turned on?
NOTICE!
Your ceiling fan and light kit assembly must meet the following
requirements:
1. 4 speed DC motor fans only.
2. Electrical rating: 120V 60Hz 3.25A
MAX. motor amp: 2.0A
MAX: incandescent lamp watt 150W or
MAX: LED lamp watt 120W
3. Operating ambient temperature: 0 °C to 40 °C
4. Indoor use only
5. NEMA Type 1 Enclosure
For Warranty Information please visit www.hinkley.com