13.56 MHz - High-security flush-mounted reader
Installation instructions
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN 62368-1) for the main supply.
Main power supply:
Consumption:
RS485:
RS232:
Wiegand / Clock & Data:
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (SCB / OCB) or controlled by the remote system with a 0 Vdc
respectively on the "Led 1", "Led 2" and "Buzzer" inputs of the reader's or controlled by the communication protocol of the reader (SSCP / OSDP
Tearing is detected by an accelerometer. When the reader is wrenched:
▪
for R/S 31: the wrenching signal will be emitted on the "Data/Data1" line. This function is configurable via a configuration card.
for R/S 32/33 and OSDP
▪
for W 32/33: the reader will perform the operations configured with the SSCP protocol.
▪
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
On power-up, the reader enters an initialization phase:
1.
Activation of the white LED and buzzer for 100 ms.
For read-only and OSDP
readers:
TM
2.
Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3.
For serial R/S ARC only: the orange LED flashes 20 times: waiting for an update.
4.
Activation of the default LED (read-only: flashes blue, OSDP
R and S readers are configurable with the SCB configuration card created with SECard. OSDP
▪
If the SCB/OCB is compatible with the reader's firmware, the LED lights green and the buzzer beeps five times.
If the SCB/OCB is not compatible with the reader's firmware, the LED lights red and the buzzer is activated for 1 s.
▪
If the SCB/OCB key is different from the reader's key: no reaction.
▪
Caution: set your reader with your own company key.
For data signals, 10k pull-up resistors are connected internally to V
Available Baud rate
Factory Baud rate
Mode
Number of bits
Transfer mode
Stop bit
RS485
Wiring resistors R1 and R2 use extended features of the RS485 bus: FAIL-SAFE (see RS485-AN-960).
R1 & R2: 1.5 kΩ resistor.
R
: 120 Ω end-of-line resistor.
T
▪ The supply voltage at the reader's connector should be between +5 Vdc and +24 Vdc.
▪ As far as possible, keep the reader away from computer or power source cables. They can generate electrical interference depending on their radiation level and
the proximity of the reader.
▪ Recommended distance between two readers: parallel plane: 11.81 in – same plane: 15.75 in – perpendicular plane: 9.8 in.
▪ Place the reader at a height of less than 2 meters.
▪ Readers installed on a metal surface may have reduced performances.
▪ Use a ferrite (two-way) for the cable (power supply and data). Example: Reference 74271222 WURTH ELEKTRONIK.
▪ Indoor use.
▪ Operating temperatures: -4°F to +158°F.
▪ BEFORE powering on, connect the wires or the connector of the reader. Before disconnecting the wires or the connector of the reader, power off.
STid declares that the WAL2-x3x-E reader is compliant to the essential requirements of the Directives RED 2014/53/EU and RoHs 2011/65/EU + 2015/863. A copy of
our declaration is available on request from qualite@stid.com.
This device complies with Part 15 of the FCC rules and with ISED's license–exempt RSSs. Operation is subject to the following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference that may cause undesired operation.
Note: the manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications
could void the user's authority to operate the equipment.
This device complies with the safety requirements for RF exposure in accordance with RSS-102 issue 5 for conditions of use and with §1.1307(b), 2.1091
and 2.1093 of the FCC rules Title 47 CFR Ch. I.
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's license-
exempt RSS(s). Operation is subject to the following two conditions:
1) This device may not cause interference.
2) This device must accept any interference, including interference that may cause undesired operation of the device.
STid reserves the right to make change without notice, for the purpose of product improvement.
Range +5 Vdc to +24 Vdc
Typical consumption
Max consumption
Use a multi-conductor shielded twisted pair cable. Max. length: 3281 ft at 9600 baud
Max. length 49.2 ft
Use an untwisted shielded multi-conductor. For data:
2 wires AWG24 – 98 ft max / 4 wires AWG24 – 197 ft max / 6 wires AWG24 – 328 ft max
2 wires AWG20 – 164 ft max / 4 wires AWG20 – 328 ft max
: the reader will perform the operations configured with the configuration card.
TM
9600, 19200, 38400, 57600, 115200 bauds
ARC R & S: 9600; ARC W: 38400 (SSCP), 9600 (OSDP
Default broadcast address 00h
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1094A04 - Page 2 sur 5 - Ed. 18/05/2021
Power supply characteristics
Typical: 12 Vdc
+5 Vdc
+12 Vdc
140 mA
80 mA
170 mA
100 mA
Recommended cables
Buzzer / LED
Anti-tearing
Powering-up the readers
: off; if no customer specific configuration).
TM
Reader configuration
readers are configurable with OCB configuration card:
TM
TTL pull-ups
(power supply voltage) for optimal wiring distances.
in
RS232 / RS485 communication
Asynchronous
8
LSB first
1
Bus architecture (RS485)
Precautions for installation
Declaration of compliance
+24 Vdc
50 mA
70 mA
TM
)
More details about reader
communication are available
in the protocol specification.
US
FR
ES
TM
).