SAFETY INSTRUCTIONS
READ THIS FIRST
KEEP THESE INSTRUCTIONS
This fixture is intended for installation in accordance with the National
Electric Code (NEC) and Local code specifications. Failure to adhere to
these codes and instructions may result in serious injury and/or property
damage and will void the warranty.
1) WARNING: This fixture is not to be installed within 10 feet (3M) of a pool,
spa or fountain.
2) This fixture is to be used only with a power unit (transformer) rated a
maximum of 300 W (25 AMPS) 15 volts.
3) The #18 ga. fixture wire is not intended for direct burial.
4) Direct burial rated wire is to be buried a minimum of 6" (152mm) beneath
the surface of the ground.
NOTE: If additional Direct Burial wire is needed, contact your local Kichler
landscape distributor.
• 8 GA wire can be purchased in length of 250' (76 M), 15503-BK.
• 10 GA wire can be purchased in length of 250' (76 M), 15504-BK.
• 12 GA wire can be purchased in lengths of 100' (30 M), 15501-BK; 250'
(76 M), 15502-BK; 500' (152M), 15505-BK; and 1000' (304 M), 15506-BK.
5) Fixture shall not use a tungsten halogen lamp unless the fixture is marked
for use with such lamps.
6) Wiring connections must be made with approved/listed wire connection
device(s) suitable for the application. Do not exceed manufacturers' wiring
combination specifications for size and quantity of conductors.
ASSEMBLY AND INSTALLATION
1) Determine desired location for mounting fixture.
2) Using mounting bracket as a template, mark position of mounting holes.
Also mark bottom edge of mounting bracket.
3) Drill 3/32" (2 mm) pilot holes in mounting surface at positions marked.
Also drill 1/4" (6 mm) wireway hole. Position wireway hole directly under
pilot holes and approximately 1/2" (12mm) below line marking bottom of
mounting bracket.
4) Assemble mounting bracket to mounting surface using provided screws.
5) Pass wire through wireway hole.
6) Insert bulb.
7) Carefully slip housing over bulb and mounting bracket. Slide housing down
until snug.
8) TURN OFF POWER. Disconnect or unplug transformer.
9) Make wire connections using supplied Quic Disc
below, or using other approved wiring connection method (not supplied.)
Turn off power.
The full length of the 18 GA fixture wire may be used to connect with the 10 GA or 12 GA cable provided the following conditions are met:
• Wiring is to be protected by routing close to the fixture or accessory or secured to a building structure such as house or deck.
• 18 GA fixture wiring is to be cut off so that it is attached to the connector within 6 inches of the fixture or building structure.
• If it is necessary to make the connections underground, then no more than 6 inches of the 18 GA fixture wire is to be buried.
The Quic Disc
Place the 10 gauge supply wire across the area marked 10 GA on Quic Disc
on Quic Disc
Place the 18 gauge fixture wire across the area marked 18 GA on the Quic Disc
Disc
to the base with supplied screw, making sure that the wires remain flat in the bottom portion of the Quic Disc
all the way down.
The copper contacts will automatically pierce the wires' insulation. Excess 18 GA fixture wire that sticks out the end of the Quic Disc
Make no other wiring connections to the 18 GA fixture wire.
Date Issued: 11/25/11
following instructions
connector is designed to install one fixture and accommodates one 18 GA fixture wire and one 10 GA or one 12 GA supply wire.
.
For warranty information please visit: http://www.landscapelighting.com/portal/warranty_page
Para informacion de la garantia por favor visite: www.landscapelighting.com/portal/warranty_page
MOUNTING BRACKET
CONSOLA DE MONTAJE
SCREW
TORNILLO
®
HOUSING
CUBIERTA PROTECTORA
Quic Disc
WIRING INSTRUCTIONS
or place the 12 gauge supply wire across the area marked 12 GA
. After the wires are in place, connecta the top of the Quic
, and the screw is tightened
is to be cut off.