Mounting The Encoder - Avigilon ENC-4PORT-2AI Guia De Instalacion

Ocultar thumbs Ver también para ENC-4PORT-2AI:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40

Mounting the Encoder

The encoder can be mounted in a 19" rack by attaching it to the ENC-
BRK1U encoder bracket that can be purchased separately. The
bracket takes up only 1U of rack space and can hold 3 encoders.
Figure: ENC-BRK1U rack mountable bracket with 3 encoders.
The encoder can be attached to the bracket by lining up the four holes
on the bottom of the encoder with the hole pattern on the bracket and
screwing them together with the screws provided with the bracket.
Warning —
4
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of
the rack environment may be greater than room
ambient. Ensure that the ambient temperature
inside the rack does not exceed the maximum
operating temperature of the encoder.
Ensure that sufficient airflow is provided in the
rack environment such that safe operation of the
equipment is not compromised.
Mounting of the equipment in the rack should be
such that a hazardous condition is not created
due to uneven mechanical loading.

Publicidad

Tabla de contenido
loading

Tabla de contenido