en
(1) Learner button
(2) Socket manual switch
(3) LED blue
(4) LED red
(5) Socket A-lifts (not used here)
(6) DC input power
(7) Socket B-lifts
(8) Socket IR eye
2
Remote control for electric lifting systems
Installation
a) Connect the power supply and the motor unit to the remote receiver. Two different
plug sizes make this connection only possible to make in the right way. After having
connected the plugs, the blue light will be lit.
b) Push the emitter buttons and the motor unit will move up and down.
c) For stopping the motion one of the buttons need to be pushed again
Learning
a) If the remote receiver does not respond when pushing the emitter buttons,
reset the receiver. After that, code the emitter and receiver together again.
b) In perfect conditions it is possible to code up to 10 remote emitters to the remote
receiver but reliability of all lifts operating can be affected by things such as battery
condition and interference from other RF equipment, therefore a maximum of 4-6 lifts
is suggested depending upon the importance of this features reliability.
Coding of emitter
a) Push the learner button on the receiver for less than one second.
b) Push one of the emitter buttons - the red light will start flashing and afterwards turn off.
d) The units now are coded together with a unique code.
Reset
a) Push and hold down the learner button on the receiver for 10 seconds - will be reset
when the red light start to blink. Now follow the learner process to recode the emitter.
External rocker switch
a) This should always be fitted somewhere accessible in case the RF handset or battery
fails.
Trouble shooting
a) All testing should be done using the rocker switch. If just the emitter is not working
then follow the learner instructions and also try a new battery. The tiny LED light on the
emitter does not indicate that battery condition is sufficient. The learner process must be
followed after the battery is replaced. Occasionally, on a brand new emitter the battery
may be weak due to battery manufacturing.
b) Check all plug connections, especially check that the receiver sockets in the white plug
connections have not been pushed back.
c) If you can hear the relays in the RF box clicking and the blue light is on then power is
reaching the RF receiver. When you press and hold the rocker then the red light on the
receiver should come on. If this is happening, but no movement then it is likely that no
power is reaching the lift from the output connection. Alternatively there is a problem
inside the lift.
d) See www.hafele.com, Services, Customer Services. You will need a photo of the
CE label from the lift and details of when and where the lift was purchased.
Battery change
a) Remove the three screws on back side
b) Remove the lid on back side
c) Lift up old battery. In case of a leaking battery wear protection gloves.
d) Place new battery with positive polarity pointing to the mark VCC on the PCB.
e) Place lid on back side and tighten the three screws
Disposal
Do not deposit used batteries with the household waste use special waste collection
facilities for used batteries.
Declaration of conformity
The full text of the EU Declaration of Conformity is available with the product on the
following website: www.hafele.com.