4
961 INTERFACE
961 INTERFACE Controls
(1)
(2) (4)
(3)
(5)
(7)
(6)
(8)
(EN) Controls
AUDIO IN – Use this 3.5 mm jack
(1)
to route an audio signal into the
module for conversion to a V-Trig
(voltage trigger) signal. The
audio signal passes through the
SENSITIVITY control before being
converted, and the final, converted
signal then exits the module at the
V-TRIG OUT parallel connections
immediately to the right of the
SENSITIVITY knob.
SENSITIVITY – Use this knob to
(2)
adjust the gain of the audio signal
coming into the module through
the AUDIO IN jack. Rotate the knob
until you find a setting that gives
you the best audio-to-voltage
conversion.
V-TRIG OUT – Use the parallel
(3)
jacks to route the converted audio-
to-voltage V-Trig signal back out of
the module via cables with 3.5 mm
TS connectors.
S-TRIG IN – Route S-Trig
(4)
(switch trigger) control signals
into the module via cables
with 3.5 mm TS connectors for
conversion to V-Trig (voltage
trigger) signals. The converted
V-Trig signal comes back out
of the module via the parallel
V-TRIG OUT jacks immediately
to the right of the S-TRIG IN jack.
V-TRIG OUT – Use these parallel
(5)
jacks to send the converted V-Trig
signal back out of the module via
cables with 3.5 mm TS connectors.
5
Quick Start Guide
V-TRIG IN A/B – Use these
(6)
rows of 3.5 mm jacks to route in
multiple V-Trig (voltage trigger)
signals for conversion to an S-Trig
(switch trigger) signal that exits
the module via the S-TRIG OUT
jack assigned to this section of the
module. The V-TRIG IN A row of
inputs go straight to conversion
and output, while the V-TRIG
IN B row of inputs pass through
the SWITCH-ON TIME control
before being combined with
the converted A signal for final
output through the S-TRIG OUT
jack. When any valid V-TRIG input
activates the S-TRIG output, any
other V-TRIG input activity will be
ignored until the first V-TRIG cycle
has ended.
SWITCH-ON TIME – Use this
(7)
knob to manually limit or extend
the "ON" time duration of V-Trig
signals coming in through the
V-TRIG IN B row of input jacks. The
"ON" time can be varied from 40
milliseconds to a full 4 seconds.
S-TRIG OUT – This jack routes
(8)
the final S-Trig signal from the
V-TRIG IN A/B jacks back out of the
module via cables with 3.5 mm TS
connectors.