Assembly
1
Flush through the supply pipes.
2
Mount the ball S - unions.
3
Fasten the mixer using ball union nuts, align
and tighten it.
4
The ball - S - unions enable inaccuracies in
the wall installation to be compensated for,
whether in the horizontal direction, in the
vertical direction or in the parallel
orientation.
5
Screw the flanges down to the wall.
The hot and cold supplies must be of equal
pressures.
Adjustment
Correction is necessary if the temperature
measured at the take off point differs from the
temperature set on the scale. To adjust please
see page 7
Operation
The mixer is operated by turning the handle on
the left hand side. The green knob limits the rate
of flow to approx. 10 l/min. If a higher water
consumtion is required press the ECOSTOP
button and turn handle further.
The temperature is selected by turning the
graduated handle on the right side. The flow of
the bath mixer can be changed from tub to
shower function by simply pulling the diverter
knob located at the top of the outlet.
When the water is shut off the flow returns
automatically to the bath function.
4
All manuals and user guides at all-guides.com
English
Temperature limitation
The temperature is limited by the safety check to
38 C (100 F). If a higher temperature is
required, it is possible to override the safety stop
by depressing the safety button.
To guarantee the smooth running of the
thermostat, it is necessary from time to time to
turn the thermostat from total hot to total cold.
The mixer is equipped with non return valves and
filters. If the water flow drops the non return
valves need to be cleaned. For that purpous the
mixer has to be removed from the wall. The
filters are located in the connection pieces
underneath the connecting nuts.
Important!
The non return valves must be checked once a
year.
ECOSTAT in conjunction with flow heaters
When using the Ecostat with combination boilers,
the Ecostop safety set "A" has to be removed. If
fitting a hand shower remove the water limiter
from the shower. see page 8
If the continuous water heater causes any
problems, or you have different water pressures
you must install a water limiter to the cold supply,
(ordered separately,article number 97510000).