TS100 Cable Fault Finder
Users Guide
±2 feet (±609 mm) for cables less than 10 feet (3 mm)
Length Accuracy
±5 feet (±2 meters) for cables longer than 10 feet (3 meters) and shorter than 200 feet (60
meters)
±3 % and ±5 feet (±2 meters) for cables longer than 200 feet (60 meters)
An AC voltage of more than 5 V rms will trigger the High Voltage Warning.
High Voltage
Detection
Maximum of 4 complete measurements per second, decreasing to 2 seconds per
Measurement Rate
measurement based on cable size and uniformity.
Adjustable from -20- to -99-, retained during power off. Default to -66- when batteries are
VOP
changed
Time Domain Reflectometry (TDR) with 50 drive impedance, 6 V maximum pulse height
Measurement
Technology
Indicator flashes when battery voltage falls below 4.1 V
Low Battery
Approximately 1 kHz at an amplitude of 80 % of battery voltage. Variable frequency and
Tone Injection
cadence. Tone characteristic is changed as cable condition changes to "normal-open" from
any other condition.
Virtually all two or more conductor cables
Cable Type
Temperature
Range
32 °F to 131 °F (0 °C to 55 °C)
Operating
-40 °F to 158 °F (-40 °C to 70 °C)
Storage
Humidity
0 % to 80 %
Operating
0 % to 100 %
Storage
1 lb (454 grams)
Weight
9,843 ft max (3,000 m max)
Operating Altitude
Meets 300 V CAT none, Pollution Degree 2
Safety
Meets IEC 61326-1: Portable. Meets FCC CFR Title 47, Part 15, Subpart B
EMC
16
Notes
Patents 6160405, 6285195, 6323654, and 6509740.
This product has been safety certified for indoor use only.