Problem
Possible Causes
Temperature setting may be higher
than the ambient room temperature
The heat exchanger on the indoor
or outdoor unit is dirty
The air filter is dirty
Poor cooling
The air inlet or outlet of either unit
performance
is blocked
Doors and windows are open
Excessive heat is generated by
sunlight
Low refrigerant due to leak or
long-term use
There' s too much or too little
refrigerant in the system
There is air, incompressible gas or
The unit
foreign material in the refrigeration
starts and
system.
stops
System circuit is blocked
frequently
The compressor is broken
The voltage is too high or too low
The outdoor temperature is lower
than 7°C (44.5°F)
Poor heating
Cold air is entering through doors
and windows
performance
Low refrigerant due to leak or
long-term use
Solution
Lower the temperature setting
Clean the a ected heat exchanger
Remove the filter and clean it according
to instructions
Turn the unit o , remove the obstruction
and turn it back on
Make sure that all doors and windows are
closed while operating the unit
Close windows and curtains during
periods of high heat or bright sunshine
Check for leaks, re-seal if necessary and
top o refrigerant
Check for leaks and recharge the system
with refrigerant
Evacuate and recharge the system with
refrigerant
Determine which circuit is blocked and replace
the malfunctioning piece of equipment
Replace the compressor
Install a manostat to regulate the voltage
Check for leaks and recharge the system
with refrigerant
Make sure that all doors and windows are
closed during use
Check for leaks, re-seal if necessary and
top o refrigerant
29