75820-39
TIMER PROGRAMMER FOR WINDOW BLINDS
Buttons to raise or lower window
blinds in raise or lower menu.
c
Menu access button. Confirm flashing
value.
Button for returning to previous option.
INSTALLATION
GB
Connect according to diagram 1 (exit mode Press)
diagram 2 (exit mode FIXED).
OPERATION
The following information is displayed on the main screen:
- Day of the week.
- Time and date.
- Schedule of settings established for that day.
:Raise the window blind. If the button is pressed again whilst rising, the blind will
stop
:Lower the window blind. If the button is pressed again whilst lowering, the blind
will stop
c
: No function
: Accesses the menu:
Once the menu is accessed:
:Confirm the information that is flashing
c
: Return to previous option
:Scroll up the menu / Increase the flashing value. If held down the value can be
increased faster, by 5 units per second.
:Scroll down the menu / Decrease the flashing value. If held down the value can
be decreased faster, by 5 units per second.
PROGRAMMES MENU
Menu via which weekly programming for raising and lowering the window blinds
can be set.
Raising, lowering and periods of raising/lowering at random (to simulate presence)
can be programmed.
The random periods carry out a change in the activation of the manoeuvre for a
period of time between 30 minutes and 2 hours. At the end of the period the blinds
will always be lowered.
Note: any Raising/Lowering or manual switching of programmes or a change in
the programmed date/hour, carried out whilst a random period is active, cancels
said period.
Example of programming of manoeuvre:
From Monday to Friday raise the blind(s) at 7 a.m. and lower them at 11:30 p.m.
Saturday and Sunday no manoeuvre.
We access the menu from the main screen by pressing
appear. Press . PROG01 appears. Press
RAISE appears. Press . DAY WEEK, MON: YES appears. Press . TUES: YES
appears. Press . WED: YES appears. Press . THURS: YES appears. Press .
FRI: YES appears. Press . SAT: YES appears, press . SAT: NO appears. Press
. SUN: YES appears, press . SUN: NO appears. Press . HOUR appears, press
button
until the required hour is shown, in this case 07:00. Press . MINUTES
appears. Press .
Up to this point the manoeuvre to raise blinds from Monday to Friday at 07:00 is
programmed.
For the manoeuvre to lower blinds, repeat all the steps in PROG02 selecting TYPE
LOWER and the hour 23:30.
c
Once done press
repeatedly until the main screen is returned to.
20 different programmes can be set.
If there is a power cut during the raising or lowering activation, once the power is
re-established, the activation which was interrupted will be regenerated.
ADJUSTMENTS MENU
This menu accesses the more complex functions of the device:
-Exit Submenu
Modify the action of the relays. PRESS (default option) or FIXED can be selected:
PRESS: Diagram 1: The activation presses on the relays have a maximum duration
of 2 seconds (to be installed together with 75358-39).
SIMON, S.A. Diputación, 390-392 / 08013 Barcelona
Atención Técnica al Cliente - Customer Technical Support:
Tel.902109700 E-mail:simonmail@simon.es http://www.simon.es
Diagram 1: with Art. 75358-39 RECOMMENDED.
Exit submenu PRESS (by default).
L
N
L
N
M
M
75820-39
230 V~/ 50 Hz
u
5(1)A 250V~
0T40
R24h
recommended
, or
See section Adjustments-Exit.
. PROGRAMMES will
EDIT appears. Press . TYPE
ELECTRONIC CONTROL DEVICES
M
M
N
L
M
Art. 75358-39
FIXED: Diagram 2: The activation pulses on the relays last for 2 minutes.
(Warning: observe the maximum connection power, the use of contactors is
recommended).
- CONTRAST sub-menu
Either HIGH or LOW contrast can be selected
By pressing a button, the contrast will temporarily be HIGH for 3 seconds. If after
this time has elapsed no button has been pressed, the level of contrast will once
again adjust to that selected.
- SEASON sub-menu
In this menu the daylight savings changes can be set, selecting between:
Automatic: switches to daylight saving at 2am on the last Sunday in March and
switches back at 3am on the last Sunday in October.
Manual: this allows the specific dates and times of the changes to be established.
Disabled: daylight saving changes will not be made.
- STATUS sub-menu
Programmes can be switched off for a certain period of time using this menu, without
the need to delete the settings.
The following options are available:
OFF: the device remains switched off (everything works except the programmes).
The relay remains Off.
RANDOM: the device will only work with the random programmes. The other
programmes are
ignored. This is very useful for simulating presence
NUM DAYS: the timer programming will NOT function during the number of
programmed days between 1 and 31, (for example: holiday period).
ON: Any type of programme will function.
- DELETE sub-menu
All the programmes can be deleted.
- VERSION sub-menu
The firmware version of the device can be displayed quickly in this menu.
Type: PER V1.02.
LANGUAGE MENU
The language can be set using this menu, selecting between:
Spanish, English or Portuguese.
CLOCK MENU
The device's time can be set using this menu. The values to be configured include
(in this order):
Year, month, day, day of the week, hour, minute.
Once MINUTE has been confirmed the display will automatically return to the main
screen and the time and date will be saved.
RESET
Without power the time and date will remain for 24 hours, the programmes and
parameters remain in the memory.
The device is reset by pressing the 4 buttons simultaneously.
TECHNICAL CHARACTERISTICS
- Power supply:
- Power supply tolerance:
- Frequency:
- Internal consumption:
- Operational temperature:
Contact:
- Rupture capacity:
- Recommended maximum loads:
- Precision: =
- Type of protection:
- Class of protection:
- Directives
- Mark
Diagram 2: direct to motor
Exit submenu FIXED.
L
N
The use of contactors
(Relays) is recommended.
M
M
M
230 V~/ 50 Hz
u
5(1)A 250V~
0T40
R24h
230 V~
± 10%
50 Hz.
16,5 VA Maximun capacitives (1,4 W).
between
0 ºC and +40 ºC
2 X 5 (1) A / 250 Vac
280 W
± 1 s/24 h at 23 ºC
using quartz crystal
IP 20
according to
EN 60529
II accoerding to EN 60335 fully installed
2002/95/EC (RoHS) 73/23/CEE and
93/68/CEE
(Electrical
Safety)
89/336/CEE and 92/31/CEE (CEM)
CE