CONNECTION
MOUNTING
Disconnect power supply by the phase fuse, the circuit-breaker or the switch-
disconnector combined to the proper circuit.
Check if there is no voltage on connection cables by means of a special meas-
ure equipment.
Connect the cables with the terminals in accordance with the installing dia-
gram.
Install SRP-02 device in the junction box.
Switch on the power supply from the mains.
OPERATION
Pressing shortly the programmed push-button in local mode (<2 sec.) or roller
blind switch (optional) causes the roller blind moves. Another short pressing of
the same push-button or the switch causes the roller blind stops at a required
level. Pressing the push-button or the switch longer (>2 sec.) causes comfort
mode activates (the roller blind moves in a required direction and stops according
to the adjusted time).
Pressing shortly transmitter's push-button (programmed in the central mode)
causes complete opening or closing of the roller blind.
RADIO TRANSMITTERS DELETION
Press PROG push-button of SRP-02 device for a longer time.
After 5 seconds LED red diode switches on (signal pulsates) and then it switch-
es off.
Release the push-button in SRP-02 - MEMORY IS DELETED.
LOCAL
LOCAL