Descargar Imprimir esta página

Electrical Connections - Hotpoint Ariston H 101.1/HA Manual De Instrucciones

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Electrical connections

GB
The cooker must be connected to the mains electricity
supply. It is designed to operate with alternating
current at the voltage and frequency indicated on the
data plate (see the following page).
The hob is connected to the cooker using a special
connector.
Only on
certain models
BLUE
WHITE
Replace the metal protection after performing all the
necessary hob connections. If the hob is removed
from its position, the red cap which was originally
protecting the red connector must be replaced.
.itting the power supply cable
18
BUILT-IN HOB
RED
YELLOW
GREEN
BUILT-IN COOKER
1. Open the terminal
board by inserting a
screwdriver into the
side tabs of the cover.
Use the screwdriver as
a lever by pushing it
down to open the cover
(see diagram).
2. Loosen the cable
clamp screw and
remove it, using a
screwdriver as a lever
(see figure).
3. Remove the wire
contact screws L-N-
, then fasten the wires
under the screw heads,
respecting the colour
code: Blue (N), Brown
(L) and Yellow-Green
Verde (
).
The terminal board is designed for a 400 V three-
phase connection (see diagrams below).
N
L3
L2
L1
P
N
L3
L2
L1
If the electrical system has other characteristics (see
diagrams below), carry out the electrical connection
using the connection supports provided in the box
N
L
N
L2 L1
3. Secure the power supply cable by fastening the
clamp screw.
4. Close the cover of the terminal board.
400V 3N~H05RR-.
5x2.5 CEI-UNEL 35363
P.
230V 1N~H07RN-. 3x4
CEI-UNEL 35364
400V 2N~H05RR-.
4x2.5 CEI-UNEL 35363

Publicidad

loading

Este manual también es adecuado para:

H 101.1 ix/ha