Anti-Masking PIR and Dual technology (PIR/MW) Mirror Detectors - Installation
instructions
Español
Detectores de espejo (PIR/MW) Doble Tecnología y Anti-Masking
Portuguese
Detectores de Espelho PIR e Dupla Tecnologia (PIR/MW) Anti-Mascara.
Instruções de Instalação
ENGLISH
1. INTRODUCTION
The TOWER 10 AM PIR and TOWER 12 AM Dual Technology are professional
vandal resistance Anti-Masking detectors designed for large commercial and
industrial applications providing wide coverage with superior resistance to harsh
environment, employing several revolutionary patented technologies
Features:
• V-slot recessed small window technology (patent pending) for extreme
mechanical robustness and protection from false alarms (patent pending).
• "Obsidian Black Mirrors"™ and "Elliptic / Parabolic Mirror" technology
providing over 15,000 LUX resistance to white light and multiple-solid curtain
pattern with 50% better sensitivity than comparable mirror optics (several
patents pending).
• Adaptive Active Infra-Red Anti-Masking technology providing the most
advanced reliable protection against intentional masking attempts (patent
pending).
• Optional interchangeable Long-Range Curtain mirror providing 35 m x 2.5 m
(115 ft x 8.2 ft) coverage for TOWER-10 and 25 m x 2 m (82 ft x 6.5 ft)
coverage for TOWER-12.
• Installer friendly features:
Built-in selectable E.O.L. resistors for alarm, trouble and tamper outputs.
Plug-in terminals attached to base for easy pre-wiring.
Unique sliding closing mechanism with captive screw.
Extended mounting height 1.5 m – 4 m (5 ft – 13 ft).
Low supply voltage indication.
Remote controlled walk-test input.
Optional mounting brackets.
Selectable range adapted to the protected area size by use of a Range
Selector (TOWER 12 AM).
• Microprocessor controlled, digital TMR signal processing with dual-slope digital
temperature compensation.
• Front and Back tamper.
• True "Creep zone" down looking optics.
• Pet immunity (18Kg/40lb) using a special "pet mask".
• Built-in auto diagnostic for both PIR and microwave detectors.
2. SPECIFICATIONS
OPTICAL
Wide Angle
TOWER 10 & 12
coverage
25mx30m / 90º
Far Field Of View (FOV)
11 curtains
Medium FOV
6 curtains
Event counter settings
Mounting:
Method: Surface, corner or at 45º to wall.
Height: 1.5 m – 4 m (5 ft. – 13 ft.) without bracket.
Vertical adjustment: Angled base surface provides three tilt adjustments
according to mounting height and coverage range.
ELECTRICAL
Sensors type:
PIR: dual element low noise pyroelectric sensor.
MW: X-Band Doppler module.
For UK - 10.587 GHz, for EU / USA – 10.525 GHz. For German/Czech
9.35 GHz
Maximum radio-frequency power: 27 dBm @ 10.525 GHz and 10.587 GHz
Supply voltage: 8 – 16 VDC.
NOTE: Unit shall be powered only by Limited Power Source (marked "LPS")
certified power supply
Low voltage detection: If input voltage is below 7.5 VDC.
Supply current:
Standby @ 12 VDC: 12mA (TOWER 10 AM). 15 mA (TOWER 12).
Maximum: 14mA (TOWER 10 AM). 18 mA (TOWER 12).
CAUTION: Unit must be powered from a certified Control Panel with a rated
voltage of 8-16 VDC and which has a CP supply output that is limited by a fast
blow fuse of 0.5A or 0.75A only.
D-300909 TOWER 10 AM/TOWER 12 AM Installation Instructions
.
Mirror Types (see Fig. 2)
Long Range Curtain
TOWER 10
TOWER 12
35m / 5º
25m / 5º
1 curtain
1 curtain
1 or 2
LR
14 dBm @ 9.35 GHz
TOWER 10 AM, TOWER 12 AM [GRADE 3]
EN: Yellow, red & green LEDs
SP: LEDs amarillo, rojo y verde
PT: LEDs amarelo, vermelho e verde
Figure 1 - TOWER 10 AM / TOWER 12 AM
Alarm period: 2 to 3 sec.
Masking detection delay: 30 sec.
Remote LED enable input (TST): High impedance input. Affects LEDs
operation only if internal LEDs selector is set to OFF.
Outputs:
Alarm output: Solid State Relay. NC, 100 mA / 30 V, 35 ohm maximum
internal resistance. "Open" for 2 – 3 sec. in case of alarm, masking event or
complete power failure.
Trouble output: Solid State Relay. NC, 100 mA / 30 VDC, 35 ohm
maximum internal resistance. "Open" in case of auto-diagnostic failure, Anti-
Mask event, low voltage or complete power failure.
Tamper output: NC switch, 50mA / 30 VDC. "Open" by opening detector's
cover or removing it from mounting surface.
Built-in End Of Line resistors circuit: Selectable serial resistors for each of
the three outputs. Resistors values: 0 Ohm (Factory default), 1 K, 2.2 K, 4.7 K,
5.6 KOhm (see figure 5).
LED indications:
Event / status
TOWER 12 AM
Low voltage
Yellow + Red + Green
Warm-up (60sec.)
flashing alternately
Self-test failure
AM detection
ALARM
PIR detection
MW detection
Warm-up time: 60 sec.
ENVIRONMENTAL
Operating Temperature: -20°C to 55°C (-4°F to 131°F).
Storage Temperature: -20°C to 60°C (-4°F to 140°F)
RFI Protection: Greater than 20 V/m (up to 2 GHz).
Housing: IP41 and IK04 .
Dimensions: 160x77x47mm (6-5/16 x 3 x 1-13/16 in.)
Optional ACCESSORIES:
BR-1: Surface mounted swivel bracket, adjustable 30° down and 45° left/45°
right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
CURTAIN-10/12: Interchangeable long range 35m/5° curtain mirror
PET-10/12: Pet mask provides 18Kg/40Lb pet immune for wide angle mirror
only.
Conform with Standards :
Europe: EN 300 440*, EN 301 489*, EN 50130-4, EN 62368-1, EN 50131-2-4*,
EN 50131-2-2** Grade 3 Class II
* Suitable for TOWER 12 AM
** Suitable for Tower 10 AM
Certified by Applica Test & Certification AS in accordance with EN 50131-2-2**,
EN 50131-2-4*, EN 50130-4, EN 50130-5.
Simplified EU Declaration of Conformity
Hereby, Visonic Ltd. declares that the radio equipment type TOWER 12 AM is
in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following
internet address: http://www.visonic.com/downloadcenter.
European Single Point of Contact: Tyco Safety Products, Voltaweg 20, 6101 XK
Echt, Netherlands.
3. INSTALLATION
3.1 General Guidance
(See figure 3)
3.2 Installation Procedure
(See figure 4 & 5).
3.3 Jumpers setting
3.4 Long Range Mirror mounting
Optional for TOWER-10 AM - See figure 6. For long range mirror, the COUNT
(counter) jumper should be set to "LR" position (see fig. 5).
Indication
TOWER 10 AM
Red flashing
Yellow + Red flashing
alternately
Yellow + Red flashing simultaneously
Yellow ON
Red ON
Green flashing
---
Green ON
---
(See figure 5)
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Tyco Visonic TOWER 10 AM

  • Página 1 Sensors type: internet address: http://www.visonic.com/downloadcenter. PIR: dual element low noise pyroelectric sensor. European Single Point of Contact: Tyco Safety Products, Voltaweg 20, 6101 XK MW: X-Band Doppler module. Echt, Netherlands. For UK - 10.587 GHz, for EU / USA – 10.525 GHz. For German/Czech 3.
  • Página 2: Introducción

    3.5 Pet Mask Mounting (optional) The above list includes the most common reasons for failure to detect intrusion, but is by no means comprehensive. It is therefore recommended that the detector and the For pet immunity (up to 18Kg/40lb), a special "pet mask" model PET 10/12 should entire alarm system be checked weekly, to ensure proper performance.
  • Página 3: Instalación

    Es por lo que se dirección Internet siguiente: http://www.visonic.com/downloadcenter. recomienda que los detectores y el sistema de alarma se verifiquen semanalmente, Punto de Contacto Único Europeo: Tyco Safety Products, Voltaweg 20, 6101 para asegurar su correcto funcionamiento. XK Echt, Netherlands.
  • Página 4: Comentários Especiais

    Internet: http://www.visonic.com/downloadcenter. W.E.E.E. Declaração de Reciclagem de Produtos Ponto Único de Contato Europeu: Tyco Safety Products, Voltaweg 20, 6101 XK Para informações acerca da reciclagem dete produto deve contactar a empresa onde o Echt, Netherlands.
  • Página 5 m ft. 16 52.5 90º 2±0.3m (6.5±1ft) (115ft.) (*) Recommended height (see table in fig. 4) TOWER 12 ONLY / / Altura recomendada (ver tabla en Figura 4) SOLO TOWER 12 / Altura recomendada (ver tabela na Figura 4) AM / Só TOWER 12 16 52.5 Fig.
  • Página 6 (2) / Cablagem & Configuração dos jumpers (2) EMAIL: info@visonic.com INTERNET: www.visonic.com © 2021 Johnson Controls. All rights reserved. JOHNSON CONTROLS, TYCO and VISONIC are trademarks of Johnson Controls. TOWER 10 AM, TOWER 12 AM D-300909 Rev 10 (05/21) D-300909 TOWER 10 AM/TOWER 12 AM Installation Instructions...