1. Please read all instructions before using the DynaTrap
Insect Trap and keep for future reference.
®
2. To disconnect, twist housing to the 'OFF' position, then remove plug from outlet.
3. To reduce the risk of injury from moving parts or electric shock, always turn unit off and disconnect plug when not in use and before
servicing or cleaning.
4. Always unplug before replacing lamp. Replace with same type rated 7-Watt bulb, DynaTrap
5. Do not position the unit near heat, gas, oil or other flammable materials.
6. Place out of reach from children.
7. To reduce the risk of electrical shock, do not put appliance in water or other liquid.
8. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or if it
has been dropped into water or other liquid.
9. Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
10. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
11. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
12. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
13. Do not touch fan while in motion.
14. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle. Keep cord away from sharp edges.
15. If using outdoors, use only extension cords with a tag stating, "Suitable for Use with Outdoor Appliances."
16. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
17. Only use attachments recommended or sold by the manufacturer.
18. This appliance is provided with double insulation. Use only identical replacement parts. See instructions for Servicing of Double-
Insulated Appliances.
INSTALLATION & OPERATING INSTRUCTIONS
1. Unpack unit. Save carton for off-season storage (if needed).
2. Hold the Power switch on the side of the revolving rotation door. Twist the unit to the
"POWER ON" position. When you hear a "click," the machine is turned on.
3. For best catch results leave unit on at all times, except when cleaning or servicing.
4. Catch rate activity will be higher at night. For best catch results it is recommended to
keep the unit away from competing light sources.
5. It is recommended to place the unit at least 20 to 40 feet away from where people will
be sitting.
6. This unit is all-weather resistant - designed for outdoor use including rainy conditions.
Intended for household and commercial, indoor and outdoor use.
7. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is
wider than the other). This plug will fit in a polarized outlet only one way. If the plug
does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified
electrician to install the proper outlet. Do not change the plug in any way.
8. SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance, two systems of insulation are provided instead of
grounding. No grounding means is provided on a double-insulated appliance, nor should a means for grounding be added to the
appliance. Servicing of a double-insulated appliance requires extreme care and knowledge of the system and should be done only by
qualified service personnel. Replacement parts for a double-insulated appliance must be identical to those parts in the appliance. The
symbol must be identical to those parts in the appliance. A double-insulated appliance is marked with the words "DOUBLE INSULATION",
"DOUBLE-INSULATED" or the symbol:
FCC COMPLIANCE
This device complies with part 18 of the FCC rules. This product may cause interference to radio equipment and should not be installed near
maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
USER MAINTENANCE INSTRUCTIONS - CLEANING
Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.
1. Be sure to clean the unit once per week.
2. To clean, hold the switch on the revolving rotation door and turn it to the "POWER OFF" position. After hearing the "click," the machine is
turned off. Unplug the unit.
3. For weekly cleaning, twist the cage clockwise and remove any buildup from the inside of the retaining cage and fan with a soft brush brush.
4. For major cleaning, remove the screw securing the fan housing to the light housing (A), and gently twist to separate. Do not disconnect
wires. Using the cleaning brush, remove dirt and debris from the fan housing. Once the cleaning process has been completed, check
that the connection is secure before tucking the wires into the channel, so the wires do not get pinched or cut by the fan (D). Align the
screw holes and place the light housing on top of fan housing. Secure with a click and tighten the screw to the base of the light housing.
IMPORTANT: When replacing the retaining cage – DO NOT press/push against the screen windows.
REPLACING BULB Replace with DynaTrap
The lightbulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure optimal UV
effectiveness. Even though the bulb's light may be visible to you, its ability to attract mosquitoes diminishes over time.
1. Hold the switch on the revolving rotation door and turn it to the "POWER OFF" position. UNPLUG UNIT, and allow bulb to cool before replacing.
2. Remove the screw securing the fan housing to the light housing (A), and gently twist to separate carefully, do not disconnect wires. Loosen
®
model 41050.
the screw securing the metal bracket securing the lightbulb
fingers and hand. Grasp the bulb (with your hand and fingers protected by the cloth) and gently pull the bulb from the socket (C).
3. Remove any debris from the lamp socket with cleaning brush. Insert new bulb. Reposition the metal bracket over the base of the bulb and
tighten the screw. Check that the connection is secure before tucking the wires into the channel, so the wires do not get pinched or cut by
the fan (D). Align the screw holes and place the light housing on top of fan housing. Secure with a "click" and tighten the screw to the base
of the light housing.
HOW THE DYNATRAP®INSECT TRAP WORKS
Flying insects are attracted to the unit by UV light and CO2 that is generated by the photo-catalysis between the UV lamps and special TiO2
coating. The fan then pulls the insects into the screened base, trapping
them until they dehydrate and die. The base can be removed, allowing
the contents to be periodically emptied into the trash.
bulb #41050 (or equivalent G24 Type - 56V/7W bulb)
®
(B)
and remove the metal bracket. Cover the bulb with a cloth to protect your
TROUBLESHOOTING
Problem:
Possible cause:
Correction:
Bulb does not illuminate
1. No electrical power.
1. Check plug, receptacle and fuse or circuit breaker.
and fan does not spin.
2. Check to make sure power is switched to the "ON" position.
Bulb illuminates, but
1. Shorted fan.
1. UNPLUG UNIT: Examine fan to see that it is free from
fan does not spin.
foreign material, dirt or buildup of dead insects.
Clean unit as in "CLEANING" section.
Fan spins, but bulb does
1. Bulb not seated properly.
1. Check all sockets for proper bulb seating and alignment.
not illuminate.
2. Burnt out bulb.
2. Replace bulb if needed following instructions under "Replacing Bulb".
LIMITED WARRANTY
DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. This warranty is
limited to remedy any defective part for a period of one year from date of original date of purchase. Retain your original receipt as
proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been altered,
no warranty is in force. This warranty does not apply if this unit is purchased outside the United States, excluding Canada and Mexico.
In no case shall DYNAMIC be liable for any accidental, punitive, consequential, or any other damages of any kind for breach of this or
any other warranty, expressed or implied, whatsoever. Some states do not allow limitation on how long an implied warranty lasts, so the
above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that
vary from state to state.
REPLACEMENT PARTS
41050
7-Watt Replacement UV Fluorescent Bulb (1 piece)
To see all replacement and accessory parts available for your DynaTrap, visit www.DynaTrap.com.
FOR HOUSEHOLD AND COMMERCIAL,
INDOOR AND OUTDOOR USE
Dynamic Solutions Worldwide, LLC
69 N. Locust St., Lititz, PA 17543
1-877-403-8727 (TRAP)
dynatrap@woodstream.freshdesk.com
www.DynaTrap.com
This device complies with Performance Standards
for Light-Emitting Products, 21 CFR, Part 1040,
©2020 Dynamic Solutions Worldwide, LLC
Chapter 1, Subchapter J, Radiological health.
120 V~ 60 Hz 15 W