Replacing/Removing And Installing Planer Blades - GMC 3BVSIPCF Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
Replacing/removing
and installing planer blades
CAUTION. Always ensure that the tool is switched off
and unplugged from the power supply before installing or
removing planer drum.
Your planer is fitted with a removable drum feature for a
quick drum change, allowing you to safely install a set of
blades that may be suitable for you application. The planer
GB
comes with an additional set of sharp blades.
Note: Always completely remove the planer drum prior to
installing new planer blades. For you own safety, it is not
recommended to remove the planer blades while the drum
is still installed in the planer.
CAUTION: Always ensure that the tool is switched off
and unplugged from the power supply before installing or
removing blades. Your planer is fitted with reversible blades.
Blades can be reversed when blunt. After both sides of the
blade have been used, they should be discarded.
Removing the planer barrel
1. Place the planer on its side so that the motor is facing down.
2. Raise the drum guard (22) (by
pressing on the lever) so that
the hex head screw located on
the blade barrel is exposed.
Insert the short end of the
supplied Allen key into the
head screw.
3. Press the drum spindle lock
button (21), and rotate the
barrel until it is locked into
place. Hold in the lock off
button until the barrel has been completely removed.
CAUTION. The blades are very sharp. Take care when
handling them.
Note: The blade barrel has two lock out positions.
3BVSIPCF_Manual.indd 8
All manuals and user guides at all-guides.com
4. Loosen and unscrew the hex head screw
5. When the hex head screw has been removed continue to
Removing planer blades
1. Secure the blade drum by
Note: It is recommended that
you place padding around the
drum – like a cloth when putting
it in the vice.
2. Using the supplied spanner
8
by rotating the allen key anti-clockwise.
remove the two flat washers. Now that the barrel is free
proceed to extract it out of the planer body by pulling it
towards you. Then follow on and remove the blades.
placing the drum into a vice
and have one blade (9)
accessible facing up in the vice.
(17), loosen the three clamping
screws. Slide the planer blade
from the slot in the blade barrel
in which it is retained.
4/8/09 14:57:52

Publicidad

Tabla de contenido
loading

Tabla de contenido