Operating Characteristics - Seav LR 2329 Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING CHARACTERISTICS:

Step-by-step operation:
By using either the Radio Control or the low voltage buttons to activate the fixture, you
obtain the following action:
the first impulse activates the opening mechanism until the motor time expires or the
opening limit switch is reached, the second impulse closes the fixture. If an impulse is
sent before the motor time expires or one of the two end runs are reached, the control
unit will stop both opening and closing movements. An additional control re-starts motion
in the opposite direction.
Operation with different radio control models:
Different radio control models can be programmed: store one code (1 key) for Step-by-
Step cyclic operation (Opening - Stop - Closing); store two different codes (2 keys) for
separate controls, the first for Opening and the second for Closing.
Radio control operation with 1 Key:
Using the radio control with only one key, the following function is obtained: the first
impulse commands Opening until the motor time expires. The second impulse commands
Closing of the fixture. If an impulse occurs before the motor time expires, the control
unit stops the fixture. A further impulse implements the re-starting of the motion in the
opposite direction.
Radio control operation with 2 Keys:
Using the radio control with 2 keys, the following function is obtained: the first key ("Up"
associated to the Opening direction) commands Opening until the motor time expires,
and the second key ("Down" associated to the Closing direction) commands Closing of
the fixture. If the Up command is given again during Opening, the control unit continues
the Opening motion, while if a Down command is given, the control unit stops motion.
The same procedure is valid during the Closing phase.
Automatic closing:
The control unit closes the fixture automatically without sending additional commands.
Safety Device (Photocells):
The control unit allows for the connection and control of Photocells, Pneumatic
edges (NC).
- DS Input (NC)
Commands from the Safety Device are ignored during opening, whereas during
closing they will reverse the direction of movement.
Attention: if not used this input must be jumped.
SELECTING THE FEATURES
The control unit is supplied by the manufacturer with the option of selecting important
features via DIP switch SW1, which causes the corresponding LED to turn on.
------------ DIP SWITCH SW1 ------------
Riferimento Led
DIP 1 = T. PAUSE
DIP 2 = MOTOR T. PROG .
DIP 3 = OPERATOR PRESENT
DIP 4 = LAMP./CORT.
DIP 5 = P.P / INV.
* The Operator Present function automatically excludes automatic reclosing, therefore
with DIP 3 = ON it is possible to select Operator Present during Opening and Closure
(DIP 1 = OFF) or Operator Present only during Closure (DIP 1 = ON)
14
Led spento
Led Acceso
Without aut. closing
With auto close
No
No
Flashing
Courtesy Light
Step-by-Step
Inverting
Yes
(Yes )*

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lg 2329Lrs 2329Lrs 2329 setLrh 2329

Tabla de contenido