Página 1
All manuals and user guides at all-guides.com INSTRUCCIONES DE USO Y DE INSTALACIÓN M220 / M300 / M500 Abridor de puertas de garaje merik.com.mx INSTRUCCIONES DE USO Y DE INSTALACION INSTALLATION AND USER’S MANUAL Rev. 00 - 14.10.2015...
Página 2
FIG. 1B 90° 110° max M220 / M300 M500 MAX OPENING K300 K500 W MAX MAX OPENING K300 K500 W MAX 110 ° 1075 110 ° 90 ° 1035 90 ° 1003 FIG. 2 MERIK ®Copyright 2015 - All rights reserved...
Página 3
All manuals and user guides at all-guides.com FIG. 3 FIG. 4 MERIK ®Copyright 2015 - All rights reserved...
Página 4
All manuals and user guides at all-guides.com FIG. 5 FIG. 6 FIG. 7 FIG. 8 FIG. 9 FIG. 10 MERIK ®Copyright 2015 - All rights reserved...
Página 5
All manuals and user guides at all-guides.com FIG. 11 FIG. 12 MERIK ®Copyright 2015 - All rights reserved...
Página 6
All manuals and user guides at all-guides.com MANUAL DE INSTRUCCIONES INSTRUCCIONES DE USO Y DE INSTALACIÓN M220 / M300 / M500 Abridor de puertas de garaje MERIK ®Copyright 2015 - All rights reserved...
Página 7
ELIMINACIÓN DEL PRODUCTO GARANTÍA la alimentación eléctrica y póngase en contacto con el servicio de asistencia; el uso de M220, 1 ADVERTENCIAS M300, M500 en tales situaciones puede provocar situaciones peligrosas. 1.1 ADVERTENCIAS PARA LA SEGURIDAD •...
(FIG. 4). 4.4.2 INSTALACIÓN DE LOS FINALES DE CARRERA El actuador M220, M300, M500 no incorpora finales de carrera electrónicos y, por lo tanto, es indispensable instalar en la puerta que se debe automatizar los topes mecánicos de cierre y apertura.
Merik S.A. de C.V. El material en garantia deben enviarse a • Gire la manilla en el sentido horario (FIG. 6). la sede de Merik S.A. de C.V en porte pagado y sera devuelto a portes • De esta manera el engranaje queda libre y es posible abrir manualmente debido.
Página 10
All manuals and user guides at all-guides.com INSTALLATION AND USER’S MANUAL M220 / M300 / M500 Electromechanical actuators for swing gates MERIK ®Copyright 2015 - All rights reserved...
Página 11
1.1 SAFETY PRESCRIPTIONS • Keep all parts of the M220, M300, M500 gate This installation manual is addressed exclusively opener away from heat sources and open to professionally skilled personnel. Read all the flames;...
• Fix the rod to the front plate with the supplied nut and bolt (FIG. 4). 4.4.2 INSTALLATION OF LIMIT STOPS AND SWITCHES The M220, M300, M500 operator is not equipped with electronic limit switches and it is therefore essential to ensure that the gate to be automated is equipped with mechanical opening and closing limit stops.
Maintenance must be carried out at regular intervals by qualified personnel in compliance with the provisions of statutory legislation and the regulations in force. M220, M300, M500 must be serviced at least once every 6 months or after 10.000 operating cycles since the last service.