Idiomas disponibles

REMEDY
A Open gas cock
B Reset by pressing it
C Phase and neutral inverted
D Call technical service
E Repeat ignition
F Press reset button
G Adjust boiler pressure and check circulating pump
H Adjust thermostat setting on desired temperature.
Call technical service
A-B
A Check for possible leaks in the external pipes. Check boiler gas circuit. Call technical service
A Replace not suitable components.
B Adjust gas delivery on the modulating device.
C Check that air volutes and Venturi cones of the burner are clean. If items a-b-c have been checked with
negative result call technical service
A Replace not suitable components.
B Adjust boiler thermostat at a higher temperature and check if air intake pipe/flue exhaust connection
is correct.
A Place it on winter position
B Adjust thermostat at a higher temperature or replace it.
C Check if system gate valves and radiators cocks are opened. If item c has been checked with negative
result call technical service
D Unblock by the aid of a screwdriver and check electrical supply
E Low pressure of the water in the system
A Adjust hot water potentiometer at a higher temperature and check the condition of the inlet tempera-
ture detector.