Broan QTX110SL Manual Del Usuario

Broan QTX110SL Manual Del Usuario

Ventilador con sensor de humedad / lámpara / lámpara de noche
Ocultar thumbs Ver también para QTX110SL:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

HUMIDITY SENSING
FAN / LIGHT / NIGHT LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OB-
SERVE THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have questions,
contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the ser-
vice disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance
with all applicable codes and standards,
including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equip-
ment manufacturer's guideline and safety
standards such as those published by the
National Fire Protection Association (NFPA),
and the American Society for Heating, Re-
frigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the
outdoors.
7. Acceptable for use over a tub or shower when
connected to a GFCI (Ground Fault Circuit
Interrupter) - protected branch circuit.
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
2. This product is designed for installation in
flat ceilings only. DO NOT MOUNT THIS
PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
4. Please read specification label on product for
further information and requirements.
Installer: Leave this manual
with the homeowner.
To register this product visit:
www.broan.com
OPERATION
The humidity control, fan, light, and night
light can be operated separately. Use a 3- or
4-function wall control. Do not use a dimmer
switch to operate the humidity control or
light. See "Connect Wiring" for details.
SENSOR OPERATION
The humidity-sensing
fan uses a sophis-
ticated humidity sensor that responds to:
(a) rapid to moderate (user-adjustable)
increases in humidity or (b) humidity above
a user-adjustable set-point (50%-100%
relative humidity). The humidity sensor
may occasionally turn the fan ON when
environmental conditions change. If the
fan continuously responds to changing
environmental conditions, "SENSITIVITY"
adjustment may be required.
MANUAL ON WITH TIMED OFF
The humidity sensing fan has an additional
operation feature. For odor or vapor con-
trol, the fan can be energized by cycling
the power switch. Once the fan has been
energized in this manner, it will remain on
for the user-adjustable "TIMER" period (5
to 60 minutes). This period is factory-set
for 20 minutes.
To manually energize the fan:
1. If fan power switch is already ON,
proceed to Step 2; otherwise, turn power
switch ON for more than 1 second.
2. Turn fan power switch OFF for less than
1 second.
3. Turn fan power switch back ON and fan
will turn ON.
SENSITIVITY ADJUSTMENT
The "SENSITIVITY" has been factory set
for most shower applications. However,
if the fan is in a tub area or is being used
for dampness control, the "SENSITIVITY"
may need to be increased toward maximum
("MAX."). If the control is responding too
often to changing environmental conditions,
movement toward less ("MIN.") "SENSITIV-
ITY" may be required.
To adjust the "SENSITIVITY":
1. Disconnect power at service entrance.
2. Through the grille, locate the screwdriver
slot marked "SENSITIVITY".
3. Using a small, flat-blade screwdriver,
carefully rotate the "SENSITIVITY"
adjustment toward "MAX." or "MIN."
4. Turn on power and check operation by
turning on the shower or other humidity
source until the fan turns on.
5. Repeat above steps if necessary.
MODEL QTX110SL
TIMER ADJUSTMENT
The humidity sensing fan has a "TIMER"
that can be adjusted from 5 to 60 minutes
(factory-set at 20 minutes). This "TIMER"
controls the length of time that the fan re-
mains ON (a) after the sensor has stopped
sensing a rise in humidity and the humidity
level is below the user-adjustable set-point
or (b) after being energized by cycling the
power switch.
To adjust the "TIMER":
1. Disconnect power at service entrance.
2. Through the grille, locate the screwdriver
slot marked "TIMER".
3. Using a small, flat-blade screwdriver,
carefully rotate the "TIMER" adjustment
to desired setting (from 5 to 60
minutes).
4. Check operation by cycling the power
switch as instructed under "MANUAL
ON WITH TIMED OFF" or by turning
on a humidity source until the fan turns
on.
5. Turn humidity source off and time the
unit.
6. Repeat above steps if necessary.
CLEANING &
MAINTENANCE
For quiet and efficient operation, long life,
and attractive appearance - lower or remove
grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and
never needs oiling. If the motor bearings are
making excessive or unusual noises, replace
the motor with the exact service motor. The
impeller should also be replaced.
SENSOR CLEANING
The humidity sensor is mounted in the grille.
The sensor will operate most reliably when
cleaned occasionally as follows:
1. Disconnect power at service entrance.
2. Remove the grille. Use a dry dustcloth,
clean toothbrush, or lightly vacuum to
clean sensor and grille. DO NOT USE
ABRASIVE CLOTH, STEEL WOOL
PADS, OR SCOURING POWDERS.
3. DO NOT USE cleaning sprays, solvents,
or water on or near the sensor!
Page 

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan QTX110SL

  • Página 1 MODEL QTX110SL HUMIDITY SENSING Page  To register this product visit: www.broan.com FAN / LIGHT / NIGHT LIGHT READ AND SAVE THESE INSTRUCTIONS WARNING OPERATION TO REDUCE THE RISK OF FIRE, ELECTRIC The humidity control, fan, light, and night TIMER ADJUSTMENT SHOCK, OR INJURY TO PERSONS, OB- light can be operated separately. Use a 3- or...
  • Página 2: Typical Installations

    MODEL QTX110SL Page  TYPICAL INSTALLATIONS • Locate unit above (GFCI protected circuit required) or within 5 feet of shower head. • Locate unit away from heating or cooling sources which can affect humidity levels. • Do not locate near window. Unit may respond to the outdoor humidity level. • Unit must be installed in ceiling to properly sense moisture. • Locate unit only on flat ceilings up to 12 feet high for proper sensing.
  • Página 3 MODEL QTX110SL Page  1b. Mount housing anywhere between 2. Attach damper/ trusses, joists, or I-joists using hanger duct connector. bars. Snap damper / duct con- nector onto housing. Make sure connector is flush Sliding hanger bars are provided to allow for accurate posi- with top of housing and tioning of housing anywhere between framing. They can be damper flap falls closed. used on all types of framing (I-joist, standard joist, and truss construction) and span up to 24”.
  • Página 4: Service Parts

    99420665 Thumbscrew, #8-18 x .375 To qualify for warranty service, you must (a) notify Broan at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect * Parts not listed are included with Assembly.
  • Página 5: Limpieza Y Mantenimiento

    MODELO QTX110SL Para registrar este producto, visite: Página  VENTILADOR CON SENSOR DE www.broan.com HUMEDAD / LÁMPARA / LÁMPARA DE NOCHE LEA Y CONSERVE ESTAS INSTRUCCIONES OPERATION ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, AJUSTE DEL TEMPORIZADOR El control de humedad, el ventilador, la lámpara DESCARGAS ELÉCTRICAS O LESIONES...
  • Página 6: Instalaciones Típicas

    MODELO QTX110SL Página  INSTALACIONES TÍPICAS • C oloque la unidad sobre o dentro de una distancia de 1.5 m (5 pies) de la cabeza de la regadera (se requiere un circuito protegido con un GFCI). • Ubique la unidad lejos de fuentes de calefacción o enfriamiento que puedan afectar los niveles de humedad. • No la ponga cerca de una ventana. La unidad puede responder a los niveles de humedad del exterior.
  • Página 7: Conexión Eléctrica

    MODELO QTX110SL Página  1b. I nstale la cubierta en cualquier parte 2. Acople el conectador entre las armaduras, viguetas o viguetas del regulador de “I” por medio de barras de suspensión. tiro/conducto. Conecte a presión el Se proporcionan barras de suspensión deslizantes para facilitar conectador del regulador de la colocación adecuada de la cubierta en cualquier parte entre la tiro/conducto en la cubierta.
  • Página 8: Piezas De Repuesto

    Tornillo de mariposa n.º 8-18 x 0.375 Para tener derecho al servicio de la garantía, usted debe (a) notificar a Broan a la dirección y número de teléfono que aparecen abajo, (b) proporcionar el número de modelo y la identificación de la pieza y (c) * Las piezas no enumeradas se incluyen con el conjunto.

Tabla de contenido