4.4 - Error display menu

CURRENT ERRORS
The errors on the board will be displayed in sequence; otherwise,
the screen will show "no errors for display".
Keypad: To quit the "Current error display" menu and return to
the "Error display menu" press Exit or Es
To confirm press Ok
Errors:Reading error: appears if it is not possible to establish
communication with the board.
Code
Description
1
Obstacle detected during closing
2
Obstacle detected during opening
3
Faulty encoder
4
No electric power
5
Dead battery
6
Learnt run over maximum limit
7
Learning of weight failure
8
Motor polarity reversed or encoder channels inverted
9
Relative weight over maximum limit
10
Motor voltage is over maximum allowed
11
Power circuit overload protection occurred
12
Error while reading or writing eeprom memory
13
Monitored device 1 test failed command FOTO
14
Monitored device 2 test failed command FOTO
15
Monitored device 1 test failed command FOTO RALL
16
Monitored device 2 test failed command FOTO RALL
17
Monitored device 1 test failed command STOP
18
Monitored device 2 test failed command STOP
19
Excessive power electronic temperature

4.5 - Board actions menu

Table of board actions menu items.
Menu Item
4.1 - Cyclic Test
4.2 - Default Parameters
4.3 - Learning
Keypad: To quit the "Board actions" menu and return to the
"Main Menu", press Exit or Esc
To confirm press Ok
16
Description
performs the automatic door cyclic test
restores all the board's default parameters
performs the automatic door travel stroke learning proce-
dure
ERROR LOG
The error code and its description will be displayed: error no. 1 is
the most recent error.
Keypad: To quit the "Error log" menu and return to the "Error
display menu" press Exit or Esc
To scroll through the parameters press
Errors: Reading error: appears if it is not possible to esta-
blish communication with the board
Action
OFF
ON
are you sure you
want to restore the
DEFAULT values?
OFF
ON
Errors: Reading error: appears if it is not possible to esta-
blish communication with the board.
Writing error: appears if it is not possible to write a parameter
on the board during performance of a "cyclic test" or a "learning"
procedure.
or
Keypad
start (starts the test)
stop (stops the test)
yes (restores all the
values)
on
stop