Perel Tools 4605-B Manual Del Usuario página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3. Additional Safety Instructions
1. The distance between the spark guard and the grinding wheel must not exceed 2mm.
2. The distance between the workpiece support and the grinding stone must not exceed 2mm.
3. Never use damaged grinding wheels.
4. Replace the grinding wheel when the wheel has worn by 40mm.
MOUNTING THE MACHINE
The machine must be screwed to a workbench. Mark the position of the mounting holes on the workbench. Drill holes
at each of the marked positions, adjusting the diameter and depth of the holes to the screws used. Place the
machine on the workbench and insert the screws into the mounting holes. Tighten the screws.
REPLACING A GRINDING WHEEL
Always unplug the grinder before replacing a grinding wheel. Never use a cracked grinding wheel. Replace a cracked
grinding wheel immediately. A cracked grinding wheel may break into pieces when used and cause injuries.
MOUNTING AND ADJUSTING THE SPARK GUARDS
Adjust the position of the spark guards frequently to compensate for the wear of the grinding wheels. Mount the spark
guard on the wheel guard with the screw. Keep the distance between the spark guard and the grinding wheel as
small as possible (max. 2mm). Tighten the spark guard screw and lower the screen. Tighten the nut.
ADJUSTING THE WORKPIECE SUPPORTS
Adjust the position of the workpiece supports frequently to compensate for the wear of the grinding wheels. Loosen
the adjusting screw. Keep the distance between the workpiece support and the grinding wheel as small as possible
(max. 2mm). Tighten the adjusting screw.
4. Description
4605-B
2
PEREL

Publicidad

Tabla de contenido
loading

Productos relacionados para Perel Tools 4605-B

Tabla de contenido