HURAKAN HKN-ICF18T Manual De Instrucciones página 30

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
EN
In the event of abnormal operation of the cooker, turn off the power by turning the main switch
to the OFF position or by removing the plug from the socket and contact the service provider.
It is strictly forbidden to operate a unit that is known to be faulty.
The Seller and the Manufacturer may not be held liable for any direct or indirect damages that
may result from an accident or from operating a defective unit.
Protection devices
1.
Overvoltage protection
If the power supply voltage varies within the range from 80 to 280 V, the cooker settings and
the setup of required power will occur in automatic mode. When the voltage comes out beyond
the abovementioned range, the cooker will automatically transfer to the standby mode.
2.
Overheating protection
The temperature sensor monitors the temperature inside the cooker. If the sensor registers
overheating, the cooker will automatically transfer to the standby mode.
3.
Detection of small items
When the cooker surface contacts dishware with the diameter less than 80 mm or small items
(knife, fork, forceps, key, etc.), a warning sound signal will be issued.
4.
Absence of dishware or unsuitable dishware
If a saucepan is taken off from the cooker in the course of coking, or it is unsuitable for use, the
cooker will not be operative, and an error code will appear on the screen.
5.
Protective automatic shutdown
If the cooker in operation is not receiving commands during 2 hours, it will automatically shut
down.
(Exception: when the timer is set for more than 2 hours)
Fault codes
COD
FAULT
E
E0
Central control unit is faulty
E1
Dishware is missing
E2
Too low power supply voltage
E3
Too high power supply voltage
Circuit break or short-circuit of tem-
E4
perature sensor
7. TRANSPORTATION AND STORAGE. DISPOSAL
• This unit can be transported by any mode of transport in accordance with the warning labels
affixed to the container, as well as with the rules applicable to a particular mode of transport.
30
CODE
FAULT
Error in operation of the
E5
cooker or central control unit
E6
Current overload
Circuit break or short-circuit of
E7
IGBT (insulated-gate bipolar
transistor)
E8
Overheating of ceramic panel
E9
IGBT overheating

Publicidad

Tabla de contenido
loading

Tabla de contenido