OPERATION
• Position hands within 10cm of the sensor b (Fig. A): hand dryer starts automatically when hands are detected.
• Stops automatically 1 second after hands are removed from the detection zone b (Fig. A) or after 1 minute
of continuous use.
• Electrical supply: 1350W, 220-240V~ / 50Hz.
INSTALLATION
• Electrical supply 220 - 240V~ / 50Hz class I (with earth).
• The installation must conform to current local regulations in your country.
• IP23 waterproof, electronic control unit
• The hand dryer must be fitted with a differential circuit breaker with 6A protection and 30mA differential.
The hand dryer must be earthed (see ELECTRICAL CONNECTION section).
• Unscrew the 2 side screws c (Fig. B) and remove the cover a (Fig. A).
• Drill 4 holes Ø 8mm (Fig. C).
Add the shock absorbers h to the back of the base plate e.
Fix the base plate e to the wall using screws and rawl plugs f, g (Fig. D) provided. Ensure screws
and rawl plugs f, g are suitable for the type of wall material.
• In the default setting, the hand dryer will deliver hot air. To change to cold air, place the switch i (Fig. D) in position 0.
• Replace the cover a (Fig. A) without forgetting to reconnect the earth connection and tighten the 2 side screws c
(Fig. B).

ELECTRICAL CONNECTION

Electrical connection should take place before mounting the hand dryer on the wall.
• If connected with a socket, remove the stopping plug l and replace it with the grommet provided for this.
• Feed an IEC 60227, PVC insulated twin-core power supply cable (3 x 1.5mm
hole d (Fig. C).
• Connect the wires to connectors L, N and E (E = earth) tighten connector screws j onto the terminals (Fig. E).
• Replace the cover a (Fig. A) without forgetting to reconnect the earth connection and tighten the 2 side screws c
(Fig. B).
REMEMBER
• Our products must be installed by professional installers according to current regulations and
recommendations in your country, and the specifications of the electrical engineer.
• Avoid splashing the inside the hand dryer mechanism.
• Do not install the hand dryer next to a bath, shower or washbasin.
• Do not shake the hand dryer.
• Do not block the sensor or the air outlet.
• If the hand dryer malfunctions, immediately disconnect the power supply and contact our Technical Support team
• Do not install the hand dryer outside.
MAINTENANCE & CLEANING
Clean with mild soapy water using a damp cloth.
Do not use scouring powder, abrasive, chlorine, alcohol or acid-based cleaning products.
Product conforms to current European Directives.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
) k (Fig. E, not supplied) through
2
EN

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

510622510622w510622bk510622s

Tabla de contenido