Blower Installation; Gor Blower Without Electric Motor - FPZ SCL R- MD MOR IE2 Serie Manual De Usuario

Ocultar thumbs Ver también para SCL R- MD MOR IE2 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64
See INSTALLATION DIAGRAM in the first section
12.2

BLOWER INSTALLATION

Units supplied with standard set-up are ready to be installed in the
horizontal position.
The feet have holes for fixing; use the holes and choose the
appropriate type of screw.
Remove the protection on the ports before checking the rotation
direction and before final connection (A).
To connect the unit to the piping, remove the flange from the
silencer housings (B).
Screw the flanges to the pipes and clean from any impurities.
Refit the flanges on the silencer housings. Provide for a hose, as
per the initial diagrams.
The use of pressure measuring instruments is advisable (but not compulsory) in order to check that the difference
NOTE FOR THE
between the delivery and suction pressures respects the values given in the "SPECIFICATIONS" and on the
USER
machine's rating plate.

12.3 GOR BLOWER WITHOUT ELECTRIC MOTOR

Check the compatibility of the chosen electric motor with the data given in the DIMENSIONS in the first section.
Remove the screws and coupling cover (A).
Insert the key supplied with the electric motor and fit the semi-joint with the flexible coupling on the end of the blower shaft without
securing it (B).
Remove the sticker on the end of the motor shaft. Check that the key is properly positioned in the special seat. Fit the semi-joint,
leaving 5mm of key free (C).
Tighten the grub screw to secure the semi-joint (C).
Couple the electric motor to the blower and secure the motor to the base with screws (D-E).
Mate the two semi-joints (F).
Tighten the Allen screw located on the motor shaft semi-joint and check that the flexible element is free to float (F).
A
D
FPZ-MI-R-MD-MOR-GOR-IE2-15-R03
B
E
38 / 119
C
F
A
B

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Scl r- md gor ie2 serieScl r-20 md mor ie2Scl r-30 md mor ie2Scl r-40 md mor ie2Scl r-20 md gor ie2Scl r-30 md gor ie2 ... Mostrar todo

Tabla de contenido