RISK. OF. ELECTROCUTION!. . TO. REDUCE. THE. RISK. OF. ELECTROCUTION,. KEEP. ALL.
CONNECTIONS.DRY.AND.OFF.THE.GROUND...
10. A qualified electrician must hook up the electrical system.
a. Verify the electrical supply at the power source is off.
b. Be certain all switches on the Control Panel are in the "OFF" position.
c. Run water tight conduit
. From the Sump Pump and Float to the Control Panel.
2. From the local disconnect to the Control Panel. The electrician will need to drill holes in the Control Panel
for the conduit.
d. Make connections to the terminal strips as shown in the wiring diagram on the following page.
. Make the following piping connections:
a. From a pressurized water supply to the Fresh Water Makeup.
b. From the Pressure Washer Outlet to a pressure washer or garden hose.
c. From the Rain Water Overflow to storage tank for further processing or disposal. Do not send the water back
to Sump Pit.
NOTE: In most cases, you must have a permit to legally dispose recycled water.
Operator's Manual
INSTALLATION
WARNING
3