Mi-T-M BIO-20R-0M11 Manual Del Usuario página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BIOLOGICAL RECYCLING SYSTEM FLOW CHART WITH OZONE
The Sump Pump (1) draws water from the Sump Pit (2) and brings it into the Inlet (6) of the Biological Recycling System.
The Inlet Flow Control Valve (5) can be used to control the flow of the water into the unit. The Biological Recycling
Tank (7) is made up of several sections that are separated by baffles and weirs. The waste water enters through the
inlet pipe bringing it to the bottom of the First Chamber (8). The waste water then moves up through the Biological
Media (9). The media packs provide a surface for the bacteria to live on. As water passes through the Biological Media
(9), the microbes feed off of the organic compounds in the water, producing by-products of carbon dioxide and water.
From the First Chamber (8), the waste water moves over the weir, into the Second Chamber (10), moving down through
the Biological Media (9), then over the final weir into the Product Tank (11). To inject ozone into the system, water
is pulled from the Product Tank (11) by the Ozone Pump (13) and pushed through a venturi, (Ozone Injector (12))
which pulls air through the Ozone Generator (14) where oxygen in the air is converted to ozone. The ozone is then
delivered to the Product Tank (11).
Water is then pulled from the Product Tank (11) by the Transfer Pump (15) and moved into the Manifold (16) and
Pressure Tank (21). This tank holds water at 25-45 PSI until needed. When water is needed for washing, water is sent
from the Manifold (16) to the Pressure Washer Outlets (20). If the Product Tank (11) water level is low, water is added
through the Fresh Water Makeup (17) to the Product Tank (11). If the Biological Recycling Tank (7) water level is
too high, treated water is sent through the Rain Water Overflow (18) and disposed of. Direct fresh water can be used
from the Rinse Water Outlet (19).
Microbes also need air to live; an Aeration Pump (3) pumps water from the Product Tank (11) to two venturi Air Injectors
(4) that pull air into the water. From there the air bubbles move up through the Biological Media (9). Without the air in
the Biological Recycling System, the microbes will not be able to live.
Operator's Manual
11

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Bio-20r-1m11Bio-20r-0m31Bio-20r-1m31

Tabla de contenido