8. TROUBLESHOOTING
Not switching
Auto lens stays light
Stop welding immediately: Review the
and will not darken
sensitivity recommendations and adjust
when welding.
sensitivity. Clean Lens cover and sensors
of any obstructions.
Auto lens stays dark
Fine-tune the sensitivity setting by
after the weld arc
making small adjustments to the control
is extinguished, or
by turning it toward the 'Lo' setting.
the auto-lens stays
In extreme light conditions, it may be
dark when no arc is
necessary to reduce the surrounding
present.
light levels.
Note: Making sure the sensors are clean and facing
the arc; angles of 45°or more any not allow the arc
light to reach the sensors.
During test or using, in case of any malfunction,
please suspend using it and contact the local sales
agent.
SHADE GUIDE TABLE
WELDING
PROCESS
SMAW
MIG (heavy)
MIG (light)
TIG, GTAW
9
MAG/CO2
SAW
PAC
PAW
9
10
NOTA: SMAW: Shidlded Metal Arc Welding, SAW: Shielded Semi-Automatic Welding, MIG (heavy): MIG on
heavy metals, PAC: Plasma Arc Cutting, MIG (light): MIG on light alloys, PAW: Plasma Arc Welding, TIG, GTAG:
Tungsten Arc Welding(GTAW, TIG)
9
10
10
10
10
11
10
11
11
11
12
9. CERTIFICATION
The welding filters are tested for eye
protection by the following notified
body:
DIN Prüf-und Zertifizierungsstelle für
Augenschutz, Alboinstr. 56, D-12103
Berlin, notified body 0196, that provides
approval and continual quality system
under the control of the European
Commission, the German Ministry for
Work and the Central Office of the
Provinces.
We are therefore allowed to use the
following marks:
EN 379
ARC CURRENT (AMPERES)
11
12
11
12
11
12
12
13
12
13
10
11
12
13
E N G L I S H
EN 175 B
EN 166 B
13
13
13
14
14
14
12
13
14
13
14
14
14
15
15
15
15
7