Foreword
This stove is a top quality modern heating technology
product.
A large degree of user comfort and high fuel utilisa-
tion enable it to be used as high quality space heat-
ing, without having to do without the cosy atmosphere
of an open fire.
Proper installation and correct handling and care are
indispensable for problem-free operation and a long
service life. Please therefore observe all the informa-
tion given in these instructions. We are convinced that
you will then derive a great deal of pleasure from this
stove. Please keep these instructions in a safe place
so that you can read through them at the start of each
heating period.
Should you find any transport damage, please report it
to your supplier immediately as otherwise it will not be
possible to correct the damage free of charge.
Technical Data
● Nominal thermal output ................................. 5,0 kW
● Height to middle of the connector pipe
with the connection is at the back ............. 1259 mm
● Height to the top edge of connector pipe
with the connection at the top .................... 1399 mm
● Connection pipe ...................................... Ø 150 mm
● max. Weight................................................... 224 kg
● Connection combustion air ...................... Ø 125 mm
● Operating mode ........................ Intermitting burning
Regulations to be observed
● Local and building law regulations
● The stove must be installed by a professional and
connected to the chimney. The specific national reg-
ulations for safe installation of the connector must be
complied with. The connecting piece used must pos-
sess an opening for cleaning.
● The stove must be regularly checked by a profes-
sional.
● The stove has national technical approval from the
Deutsches Institut für Bautechnik (DIBt) (German
Institute for Civil Engineering) for room-air independ-
ent operation.
Due to its general technical approval, the stove
Turia Compact can be used simultaneously with
an approved ventilation system without addition-
al safety device.
The heating stove's fire door is self-closing; it is there-
fore approved for connection to chimneys with multiple
connections.
Chimney design
The chimney design is according to DIN EN 13384 - 2
or to the specific national regulations.
Necessary data
Closed operation:
● Nominal thermal output ................................. 5,0 kW
● Waste air mass flow rate ............................... 5,0 g/s
● Waste air temperature ................................... 300 °C
● Minimum delivery pressure at
nominal thermal output ....................................12 Pa
13