Resumen de contenidos para Rohde & Schwarz R&S TS-PSC0
Página 1
USER MANUAL PCI to CompactPCI Interface Kit ® R&S TS-PSC0...
Página 2
Note User Manual for ROHDE & SCHWARZ PCI to CompactPCI Interface Kit R&S TS-PSC0 3rd Issue / 04.09 / GB 1157.9091.12 All rights, also translation into foreign languages, are reserved. No part of this manual is permitted to be reproduced in any form (print, photocopy or any other method), also not for the preparation of lectures, or processed, reproduced or made available using electronic systems without written permission from ROHDE &...
Página 3
Basic Safety Instructions Always read through and comply with the following safety instructions! All plants and locations of the Rohde & Schwarz group of companies make every effort to keep the safety standards of our products up to date and to offer our customers the highest possible degree of safety. Our products and the auxiliary equipment they require are designed, built and tested in accordance with the safety standards that apply in each case.
Página 4
Basic Safety Instructions Tags and their meaning The following signal words are used in the product documentation in order to warn the reader about risks and dangers. indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Página 5
Basic Safety Instructions Electrical safety If the information on electrical safety is not observed either at all to the extent necessary, electric shock, fire and/or serious personal injury or death may occur. 1. Prior to switching on the product, always ensure that the nominal voltage setting on the product matches the nominal voltage of the AC supply network.
Página 6
Basic Safety Instructions 14. Use suitable overvoltage protection to ensure that no overvoltage (such as that caused by a bolt of lightning) can reach the product. Otherwise, the person operating the product will be exposed to the danger of an electric shock. 15.
Página 7
Basic Safety Instructions Repair and service 1. The product may be opened only by authorized, specially trained personnel. Before any work is performed on the product or before the product is opened, it must be disconnected from the AC supply network.
Página 8
Informaciones elementales de seguridad 2. Handles on the products are designed exclusively to enable personnel to transport the product. It is therefore not permissible to use handles to fasten the product to or on transport equipment such as cranes, fork lifts, wagons, etc. The user is responsible for securely fastening the products to or on the means of transport or lifting.
Página 9
Informaciones elementales de seguridad Se parte del uso correcto del producto para los fines definidos si el producto es utilizado conforme a las indicaciones de la correspondiente documentación del producto y dentro del margen de rendimiento definido (ver hoja de datos, documentación, informaciones de seguridad que siguen). El uso del producto hace necesarios conocimientos técnicos y ciertos conocimientos del idioma inglés.
Página 10
Informaciones elementales de seguridad Palabras de señal y su significado En la documentación del producto se utilizan las siguientes palabras de señal con el fin de advertir contra riesgos y peligros. PELIGRO identifica un peligro inminente con riesgo elevado que provocará...
Página 11
Informaciones elementales de seguridad Seguridad eléctrica Si no se siguen (o se siguen de modo insuficiente) las indicaciones del fabricante en cuanto a seguridad eléctrica, pueden producirse choques eléctricos, incendios y/o lesiones graves con posible consecuencia de muerte. 1. Antes de la puesta en marcha del producto se deberá comprobar siempre que la tensión preseleccionada en el producto coincida con la de la red de alimentación eléctrica.
Página 12
Informaciones elementales de seguridad 12. Si un producto se instala en un lugar fijo, se deberá primero conectar el conductor de protección fijo con el conductor de protección del producto antes de hacer cualquier otra conexión. La instalación y la conexión deberán ser efectuadas por un electricista especializado. 13.
Página 13
Informaciones elementales de seguridad 5. Ciertos productos, como p. ej. las instalaciones de radiocomunicación RF, pueden a causa de su función natural, emitir una radiación electromagnética aumentada. Deben tomarse todas las medidas necesarias para la protección de las mujeres embarazadas. También las personas con marcapasos pueden correr peligro a causa de la radiación electromagnética.
Página 14
Informaciones elementales de seguridad 6. En caso de falta de estanqueidad de una celda, el líquido vertido no debe entrar en contacto con la piel ni los ojos. Si se produce contacto, lavar con agua abundante la zona afectada y avisar a un médico.
Página 15
QUALITÄTSZERTIFIKAT CERTIFICATE OF QUALITY CERTIFICAT DE QUALITÉ Sehr geehrter Kunde, Dear Customer, Cher Client, Sie haben sich für den Kauf eines you have decided to buy a Rohde & vous avez choisi d‘acheter un produit Rohde & Schwarz-Produktes ent- Schwarz product. You are thus as- Rohde &...
Página 17
Address List Headquarters, Plants and Subsidiaries Locations Worldwide Headquarters Please refer to our homepage: www.rohde-schwarz.com ◆ Sales Locations ROHDE&SCHWARZ GmbH & Co. KG Phone +49 (89) 41 29-0 Mühldorfstraße 15 · D-81671 München Fax +49 (89) 41 29-121 64 ◆ Service Locations P.O.Box 80 14 69 ·...
Página 19
Customer Support Technical support – where and when you need it For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde &...
PCI to CompactPCI Interface Kit TS-PSC0 Content Content Applications General Additional documentation View Commissioning Installation in the host PC (root module) 3.1.1 Configuration of the PCI card 3.1.2 Installation of PCI card in the Host PC Installation in R&S CompactTSVP 3.2.1 Configuration of the CompactPCI card 3.2.2...
Página 22
Content PCI to CompactPCI Interface Kit TS-PSC0...
Página 23
PCI to CompactPCI Interface Kit TS-PSC0 Figures Figures Figure 2-1 View of the R&S TS-PSC0 Root Module ..........2-1 Figure 2-2 View of the R&S TS-PSC0 Leaf Module ...........2-2 Figure 3-1 Wiring of modules ................3-3...
Página 24
Figures PCI to CompactPCI Interface Kit TS-PSC0...
PCI to CompactPCI Interface Kit R&S TS-PSC0 Applications 1 Applications 1.1 General This manual describes the function and operation of the PCI to CompactPCI Interface Kit R&S TS-PSC0 for use in the test sys- tem Versatile Platform R&S CompactTSVP. The ROHDE & SCHWARZ PCI to CompactPCI Interface Kit module R&S TS-PSC0 is an add-on module for the universal production test platform R&S CompactTSVP (Test System Versatile Platform).
Página 26
Applications PCI to CompactPCI Interface Kit R&S TS-PSC0...
PCI to CompactPCI Interface Kit R&S TS-PSC0 View 2 View Figure 2-1 shows the root module of the PCI to CompactPCI Interface Kit R&S TS-PSC0. This module is insert- ed into the external PC. Figure 2-2 shows the leaf module of the PCI to CompactPCI Interface Kit R&S TS-PSC0.
Página 28
View PCI to CompactPCI Interface Kit R&S TS-PSC0 Figure 2-2 View of the R&S TS-PSC0 Leaf Module...
PCI to CompactPCI Interface Kit R&S TS-PSC0 Commissioning 3 Commissioning 3.1 Installation in the host PC (root module) 3.1.1 Configuration of the PCI card The PCI card is configured as a root card with activated bridge function (transparent mode). This configuration is set before the unit leaves the factory.
Commissioning PCI to CompactPCI Interface Kit R&S TS-PSC0 3.2 Installation in R&S CompactTSVP 3.2.1 Configuration of the CompactPCI card The CompactPCI card is configured as a leaf card with activated bridge function (transparent mode). This configuration is set before the unit leaves the factory.
PCI to CompactPCI Interface Kit R&S TS-PSC0 Commissioning 3.3 Layout of the StarFabric network 3.3.1 Wiring The two “The Bridge” modules (root and leaf) are connected together to set up the StarFabric network. Make certain the transmitter and re- ceiver connections (TX and RX) are connected with each other criss- cross: TX on Host PC →...
Commissioning PCI to CompactPCI Interface Kit R&S TS-PSC0 3.3.2 Placing the system in operation for the first time CAUTION! When placing the system in operation for the first time, make cer- tain the R&S CompactTSVP is turned on before the Host PC. Oth- erwise the BIOS of the Host PC will not be able to detect the PCI modules in the R&S CompactTSVP.