Installation; Technical Specifications; Safety Precautions; Location - Lincoln Electric POWER MIG 180 DUAL Manual De Instrucciones

Ocultar thumbs Ver también para POWER MIG 180 DUAL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

A-1
TECHNICAL SPECIFICATIONS 180 Amp unit (K3018-1)
Standard Voltage/Frequency
230 V
208 V
120 V
Voltage/Duty Cycle
230 V
30%
208 V
30%
120 V
20%
Welding Current Range
(208V / 230V)
30-180 Amps
(120V)
30-140 Amps
RECOMMENDED INPUT CABLE AND FUSE SIZES
Input Voltage/Frequency
230V / 208V 60 Hz
120V 60 Hz
Height
14.08 in
357.6 mm
1
If connected to a circuit protected by fuses use Time Delay Fuse marked "D".
2
Requirements for maximum output: In order to utilize the maximum output capability of the machine, a branch circuit
capable of 30 amps @ 120 volts, 60Hz is required.
Read entire installation section before starting

installation.

SAFETY PRECAUTIONS

WARNING
ELECTRIC SHOCK can kill.
• Only qualified personnel should perform
this installation.
• Only personnel that have read and under-
stood the POWER MIG® 180 DUAL
Operating Manual should install and oper-
ate this equipment.
• Machine must be plugged into a receptacle
which is grounded per any national, local
or other applicable electrical codes.
• The POWER MIG® 180 DUAL power switch
is to be in the OFF ("O") position when
installing work cable and gun and when
connecting power cord to input power.
---------------------------------------------------
INSTALLATION
INPUT – SINGLE PHASE ONLY
60 Hz
60 Hz
60 Hz
RATED OUTPUT
OUTPUT
Open Circuit Voltage
Fuse or Breaker Size
40 Amp
2
20 Amp
PHYSICAL DIMENSIONS
Width
10.37 in
263.4 mm
POWER MIG® 180 DUAL
Input Current
20 Amps @ rated output
Current
130 Amps
130 Amps
90 Amps
34 V
33 V
1
Input Amps
20
20
Depth
18.78 in
477.6 mm
SELECT SUITABLE LOCATION
Locate the POWER MIG® 180 DUAL in a dry location
where there is free circulation of clean air into the lou-
vers in the back and out the front of the unit. A loca-
tion that minimizes the amount of smoke and dirt
drawn into the rear louvers reduces the chance of dirt
accumulation that can block air passages and cause
overheating.

STACKING

POWER MIG® 180 DUAL cannot be stacked.

TILTING

Each machine must be placed on a secure, level sur-
face, directly or on recommended cart. The machine
may topple over if this procedure is not followed.
Voltage at Rated Amperes
20
17.6
19.5
Wire Speed Range
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Power Cord
Lincoln Electric
Part Number:
M22590
Lincoln Electric
Part Number:
M22589
Weight
66 Ibs
30 kg
A-1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Imt10089

Tabla de contenido