2.
Using the included 8-32 screws and washers, mount the blower in place
and tighten all screws. Confirm that the blower is securely seated in place
and there are no air gaps around the blower gasket.
3.
Plug both the 3 wire and 4 wire quick connect cords from the blower into
the appropriate receptacles located on the inside front of the hood canopy.
These cords will only fit into the receptacles one way (Figure 2).
Figure 2
SECTION 3
Installation into 10" High Canopy
1.
Remove the rear bottom plate of the hood canopy. It is secured in place
with a screw and washer on either side (Figure 3).
Bottom Plate
Figure 3
2.
Lift blower up into the hood canopy and slide the keyhole slots in the blower
mounting flange over the two studs of the hood. Slide the blower into place
and tighten the hex nuts on the mounting stud while lining up the 8 holes
in the blower mounting flange to the 8 screw studs of the hood (Figure 1).
3.
Using the included 8-32 screws and washers, mount the blower in place
and tighten all screws. Confirm that the blower is securely seated in place
and there are no air gaps around the blower gasket.
#
Qty. Description
1
1
Blower Assembly
2
1
Blower Gasket
3
8
Grommet
4
8
Washer
5
8
8-32 Screw
6
1
Capacitor
7
1
Screw
8
1
Fuse
111597005 New 3-07
Receptacles
Blower
Screw
Washer
REPLACEMENT PARTS DIAGRAM
Replacement Part #
5S1136063
5S1136100
5S1136101
5S1136102
5S1136103
5S1136104
5S1136105
5S1136106
www.airkinglimited.com
4.
Plug both the 3 wire and 4 wire quick connect cords from the blower into
the appropriate receptacles located on the inside front of the hood canopy.
These cords will only fit into the receptacles one way (Figure 2).
5.
Reinstall the rear bottom plate by fitting the back edge of the plate into the
channel located on the back of the hood and reinstalling the two screws
and washers removed in Step 1 (Figure 4).
Bottom Plate
Figure 4
SECTION 4
Finishing the Installation
1.
Install the included fuse into the electrical panel by turning the fuse cap
counter clockwise and pulling out. Insert the included 1/4" x 1-1/4" time
delay fuse in the holder and reinstall into the panel (Figure 5).
Cap
Figure 5
NOTE: If you need to replace the fuse, replace with a 1/4" x 1-1/4" Bussman
MDA-3 or equivalent 3 amp, 250V ceramic, time delay fuse only.
2.
Refer to the hood instruction manual to complete the installation, for
maintenance, and before restoring power.
3.
The blower is covered under the range hood's warranty.
8
5
Screw
Washer
Channel
Fuse
3
4
2
1
6
7
2 of 8