Fluqwater XTRA+ AGUAS LIMPIAS Manual De Instrucciones página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3. OPERATION
Connecting pressure pipe
• Screw the pressure pipe onto the pressure connector. All joint connections must be
sealed with a threaded sealing stripe.
• When using the hose, screw the right hose adapter into the pressure connector.
• Secure the hose firmly to the hose adapter and secure it with a hose clamp.
If it is used occasionally, please use a suitable pipe. A rigid pipe with a check valve is
recommended for use in a fixed position. This can be done at the close of the machine to
prevent liquid backflow.
Use a strong rope to connect the handle of the pump and dip it into the liquid to be
conveyed at a certain angle, so that the lower side of the device has no bubble formation
to prevent the bubbles from being sucked in. Put the equipment down slowly, and once
the pump is submerged, it can be adjusted again. The pump is arranged at the bottom of
a liquid container, Fasten the end of the rope after lowering so that the pump can also be
handled when hanging on the rope. The pump can work after the device is connected to
the main power source.
The pump is not allowed to transport corrosive substances, flammable
and explosive substances (such as gasoline, petroleum, nitro diluent),
grease, oil, brine and toilet equipment sewage, as well as low mobility
mud sewage. The temperature of the liquid cannot exceed 35 °C.
4. ERROR SHOOTING
In most cases, you will be able to troubleshoot problems easily by yourself. Before you
contact us, please refer to the following table for technical support. This will help you
save a lot of work and possible expenses.
E R R O R
The pump cannot start.
No water.
The pump cannot close.
R E A S O N S
• Unconnected power.
• The float switch is not
turned on.
• Inlet obstruction.
• The pressure hose is
bent.
The floater cannot sink.
E R R O R S H O O T I N G
• Check power supply.
• Lift the float switch up.
• Clean the inlet.
• Adjusting hose.
Put the pump in the vertical well
bottom correctly.