Connecting Quick Connect Cord-2
Caution
The wire coloring on the Quick Connect Cord-2 will
not be the same as the wire coloring of the
connection plug inside the unit.
* The remote controller can be connected to either
unit A or B. Do not connect a remote controller
to both units.
* Disconnect the remote controller from either unit
A or B prior to installing the Quick Connect Cord.
Connecting the Quick Connect Cord to the two units.
1. Turn off the power.
2. Remove the front cover of the heater (4 screws).
3. Pass the Quick Connect Cord through the wiring
throughway and into the unit.
4. Plug the connector on the Quick Connect Cord to
the receptacle inside the unit.
5. Attach the ground wire of the Quick Connect Cord
to the terminal block xing plate.
(If the ground wire is not attached, electrical noise
may cause problems).
6. Secure the Quick Connect Cord with a clamp.
7. Replace the front cover.
34
For Quick Connect Multi System Installation
use part TWHQCCORD only. (Sold Separately)
1.Red
2.Black
3.White
4.Green
5.Blue
6.Blue
A
Quick Connect
Cord-2
Connector
Ground wire
Connector
Wiring Throughway
1.Red
1.White
2.Black
2.Green
3.White
3.Red
4.Green
4.Black
5.Blue
5.Blue
6.Blue
6.Blue
B
"Quick Connect Cord-2" tag
Clamp