After pilot lights,
hold down pilot
button for 30 -60
seconds and then
release knob. Knob
should return to
fully extended
position; see Figure
4. To operate heater
slightly depress
knob and gently
turn to lock in the
"HI" position to light
Figure 4: "Release knob.
burner tile. Leave on
"HI" position until burner tile turns bright orange.
•
If heater does not light, hold down for approximately 30
seconds; release and depress again. Repeat until pilot lights.
•
After burner tile has turned bright orange, adjust heat
output by turning Control Knob to desired position
("LO" or "HI" setting)
Warning:
DO NOT OPERATE HEATER UNLESS CONTROL KNOB
IS LOCKED IN A POSITION MARKED "HI", "LO" or
"PILOT".NEVER SET CONTROL KNOB BETWEEN LOCKED
POSITIONS. POOR COMBUSTION AND HIGHER LEVELS
OF CARBON MONOXIDE MAY RESULT.
•
To shut off heater, slightly push down and turn Control
Knob clockwise to "OFF" position.
•
CAUTION: After turning heater off, wire guard will
remain hot. Allow to thoroughly cool before storing.
•
Do not operate, store or remove cylinder near
flammable items or ignition sources.
• LP-GAS CYLINDERS MUST BE DISCONNECTED FROM
HEATER WHEN NOT IN USE!
LIGHTING / OPERATING INSTRUCTIONS FOR
USE WITH HOSE CONNECTED TO A REMOTE
CYLINDER, MAXIMUM SIZE 20 LBS:
•
This Heater may be used in a recreational enclosure or
temporary construction work enclosure with a remote
refillable propane cylinder ONLY when the cylinder is lo-
cated outdoors and the Heater is used with Mr. Heater
Hose No. F273701, F273702 or F272702 and fuel filter
F273699. Fuel filter must be replaced annually. Or use
F273704 Buddy series hose. Fuel filter not required.
•
DANGER: NEVER bring a refillable propane cylinder
indoors. A fire or explosion can occur causing property
damage, serious injury or death!
•
Inspect the hose before each use of the heater. If there
is excessive abrasion or wear, or the hose is cut, replace
prior to using the heater with one of the Mr. Heater
Hose No's. shown above.
•
The propane cylinder must include a listed overfilling protection
device as well as a collar to protect the cylinder valve.
•
Heater must be in an upright position during operation.
•
Make sure four-position Control Knob is in "OFF"
position; see Figure 1, at left.
Mr. Heater | Portable Propane Heater
•
Swivel regulator outward for easy hose installation.
Then screw hose connector into regulator on heater and
screw connector on other end of hose into LP-gas sup-
ply cylinder valve. Tighten all hose connections. Do not
use thread sealant on any of these connections.
• Mr. Heater strongly recommends using disposable
fuel filter F273699 to trap any oil substances when
connected to a remote cylinder that can make
heater inoperable.
•
Open valve at LP-gas supply cylinder.
•
Check all hose connections for leaks with soapy water at
the threaded connection under the domed plastic cover
where the hose connector screws into the regulator and
at LP-gas supply cylinder. SEE WARNING! ON PLASTIC
DOMED COVER.
•
Turn Control Knob counterclockwise to "PILOT" position
and depress. Depress the pulse ignition button located
in the accessory compartment (see pg 6), while holding
pilot button down.
•
After pilot lights, hold down pilot button for 30 -60
seconds and then release knob. Knob should return to
fully extended position. (Fig 4) The pilot should remain
lit. To operate heater slightly depress knob and gently
turn to lock in the "HI" position to light burner tile. Leave
on "HI" position until burner tile turns bright orange.
•
After pilot lights, hold down for 30 -60 seconds and
then release knob. Knob should return to fully extended
position; see Figure 4. To operate heater slightly depress
knob and gently turn to lock in the "HI" position to light
burner tile. Leave on "HI" position until burner tile turns
bright orange.
•
After burner tile has turned bright orange, adjust heat
output by turning Control Knob to desired position
("LO" or "HI" setting)
Caution: Do not try to adjust heating levels by using
the propane tank shut off valve.
Warning:
DO NOT OPERATE HEATER UNLESS CONTROL KNOB
IS LOCKED IN A POSITION MARKED "HI", "LO" or
"PILOT".NEVER SET CONTROL KNOB BETWEEN LOCKED
POSITIONS. POOR COMBUSTION AND HIGHER LEVELS
OF CARBON MONOXIDE MAY RESULT.
•
To shut off heater, shut off propane at supply tank,
allow heater to use up propane in supply line un-
til heater shuts off, then slightly push down and
turn Control Knob clockwise to "OFF" position.
•
CAUTION: After turning heater off, wire guard will
remain hot. Allow to thoroughly cool before storing.
•
When not in use, the gas must be turned off at the LP-
gas supply cylinder. As stated before allow heater to use
up propane in supply line until heater shuts off. When
the LP-gas supply cylinder is not disconnected from the
heater, the heater and the cylinder must be stored
outdoors, in a well ventilated space, out of reach of
children, and must not be stored in a building, garage
or any other enclosed area.
5
Operating Instructions and Owner's Manual