No.
Mat. no.
Designation
1
Plug N1Q_ST11A
1
Wiring harness 1N1-16, 2N1-16 L, N
1
Wiring harness 1N1-16, 2N1-16 Bus
3
Connecting wire, brown 90 mm
1
Screw connector strip, 4-pole, lilac
1
Screw connector strip, 6-pole, blue
1
Screw connector strip, 7-pole, green
1
Terminal strip 3X3-4, orange / grey
1
Terminal strip 4X3-4, blue / green / yellow
1
Liquid dispensing accessory
1
Holding bracket for electronic unit
2
Fixing plate for holding bracket for electronic unit
4
Raised-head screws, CEM 6 x 12
6
Cable gland M12
6
Cable gland M20
1
Wiring diagram
Danger due to incorrectly carried out service and repair work
WARNING
Danger due to incorrectly carried out service and repair work
There is a risk of serious damage, injury and even death if service and repair work is carried out incorrectly.
A
Service and repair work should only be carried out by a suitably qualified electrician with specialist training,
knowledge and experience.
A
All appropriate safety regulations must be taken into account.
A
First read the Technical Service Documentation (TSD), then commence work.
Risk of injury due to sharp edges
CAUTION
There may be a risk of injury due to sharp edges.
Risk of injury due to sharp edges!
A
Protective gloves should be worn and the edge protection, Mat. no. 05057680, should be used.
Installing module 3 for liquid dispensing 7-11 and water recycling
A
Remove the machine lid, see the model-specific TSD.
A
Mount holding bracket (3) for the electronic unit with fixing plate (2) onto the cross support, see Fig. 1.
A
Secure module (1) with holders (2) onto the holding bracket (3), see Fig. 1.
A
Fit terminal strips (5) in the pre-punched holes of the cross support, see Fig. 1.
A
Fix cable screw connectors (1) to the top of the back panel. To do this push the relevant embossed holes out of the
top of the back panel, see Fig. 2.
A
Connect screw connector strip 7-pole, green to ST8 on the module, see Fig. 3.
A
Connect screw connector strip 4-pole, lilac to ST11 on the module, see Fig. 3.
A
Connect screw connector strip 6-pole, blue to ST12 on the module, see Fig. 3.
A
Connect coding plug MFM 53X to ST7 on the module, see Fig. 3.
A
Connect coding plug WRG1 to ST6 pin 2-3 on the module, see Fig. 3.
28.09.2017