— Attention: The built-in temperature switch cuts off the device if it overheats
— Disconnect the transformer from the power supply.
— Eliminate the cause of the fault.
— When installing the transformer, ensure that it is far enough away from the
— The installed capacity of the lamp may not exceed the capacity of the
Assembly (fig. 1 - 7)
— Assemble the swivel bracket (fig. 5).
— Place the nut into the hole in the side.
— Set the swivel bracket into position and lightly screw the bolt into the nut.
— Secure the bracket in position using the screws.
— Connect the spotlight and the OASE safety transformer using the secondary
— Position the spotlight so that it does not present a danger to anyone.
— For use in the pond attach the spotlight to a suitable base (stone) using the swivel
— For use outside the pond use the stake and the swivel bracket.
— Insert the connector of the safety transformer into the socket fig. 2).
— Check the function of the spotlight.
Technical data
Lunaqua 35
Rated voltage
Power consumption
Spread of light
Transformer
Rating
Primar voltage
Secondary voltage
Changing the bulb (fig.1)
1. Turn off the light or the safety tranformer and ensure that it cannot be accidently
turned on.
2. Loosen the screws of the upper section.
3. Remove the upper section and the glass and clean, if ecessary.
4. Remove the bulb from the fitting and replace. Do not touch the glass of the bulb
with your hand.
5. Take note of the power information on the bulb.
6. Check the O-ring and replace it if damaged.
7. Reassemble the parts in the reverse order.
Lunaqua35 Exp.p65
GB
Operating instructions
(fault) and switches it on again automatically once it has cooled down.
Subsequently, proceed as follows:
lamp to prevent it from being additionally heated up by the heat radiating from
the lamp.
transformer as specified by the type plate.
side plug connector.
bracket.
7
12 V / 50 Hz
35 W
24°
35VA
230 V / 50 Hz
12V
28.03.2003, 09:23
GB
7