1. Fit the Flex UV-C with the three-piece couplings (I) in the circuit and place the caps
with the nut on the inlets/outlets that are not being used, and tighten them.
2. Fit the unit with the pipe clips (O) (supplied with the set) at a permanent
installation point and tighten the three-piece coupling (I).
3. Fit the lamp (K) in the lamp holder (L); than slide the lamp (K) carefully into the
quartz glass (M) and tighten the screw nut (N) finger-tight on the unit.
4. Start the pump and check the flow of the system and that it is not leaking. Then check the seals
(P) for correct positioning both at the connections and the quartz glass (see drawing 2).
5. Plug the power lead of the UV-C device into an earthed electrical socket with an earth leakage switch.
Check that the lamp lights up; this can be seen through the transparent attachments on the device.
6. The device is switched off by removing the plug from the electrical socket.
7. Make sure there is enough room left (+/- 1 mtr.) to remove the lamp (K)/
quartz glass (M) for replacement and/or maintenance.
DISMANTLING/MAINTENANCE (DRAWING 2)
During maintenance/dismantling always disconnect electrical current. The device needs to be cleaned at
least twice a year. If algae or lime scale forms on the quartz glass tube (M) containing the lamp, it must be
cleaned. The special lamp must be replaced after 9,000 hours. Clean the aluminium interior with a soft brush.
1. Unscrew the three-part couplings (I) and allow the water to flow out of the device.
2. Twist the nut (N) containing the lamp off the device and replace the lamp (K)
if needed. Please handle with care as these are very delicate parts.
3. Carefully remove the quartz glass (M) with a large flat screwdriver (see drawing 3). Never force it!
4. Clean the quartz glass with an appropriate solution. Always use a
soft cloth to clean the glass to prevent scratches.
5. When replacing the quartz glass in the housing make sure that it is placed on the seals (P) correctly
and carefully slide the end of the quartz glass into the receiving guide (Q) (see drawing 4).
If the housing or the electrical section must be replaced then the earthing should first be disconnected
from the housing. When assembling a new housing or electrical section then please read Installation and
Dismantling first. Make sure that you keep the various bits of the earthing properly. These are not supplied with
a new housing or electrical section. If there is any doubt about the connection, consult a certified electrician.