Los módulos de entrada y el módulo de entradas / salida

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Fig./Abb. 1
1:2 DIN
1:1 M200E-SMB
Sollevare
Levantar
Anheben
Fig./Abb. 2
Fig./Abb. 3
Fig./Abb. 4
M210EA: DOP-IOD070
0905
M220EA: DOP-IOD071
21
M221EA: DOP-IOD072
EN54-17: 2005, EN54-18: 2005
D200-500-00
M210EA M220EA M221EA
22 mm
60°C
-20°C
2
1
Rotate
Plug
Ruotare
Inserire
Girar
Conectar
Drehen
Einhaken
Clip / Agganciare
3
Acoplar / Einrasten
3
1
Lift
Push down
Premere
Precionar
hacia abajo
Runterdrücken
2
Rotate / Ruotare
Girar / Drehen
M210EA
M220EA
M221EA
(i)
+
(iii)
Fig./Abb. 5
Honeywell Products and Solutions Sàrl
(Trading as System Sensor Europe)
Zone d'activités La Pièce 16
CH-1180 ROLLE, Switzerland
Pittway Tecnologica S.r.l, Via Caboto 19/3, 34147 Trieste, Italy
EN
INSTALLATION INSTRUCTIONS - M210EA / M220EA
INPUT MODULES, M221EA INPUT /OUTPUT MODULE
This manual is intended as a quick reference installation guide. Please refer to the
control panel manufacturers installation manual for detailed system information.
The M200 series of modules are a family of microprocessor controlled interface
devices permitting the monitoring and/or control of auxiliary devices.
M210EA SINGLE CHANNEL INPUT MODULE
Provides single channel monitoring of normally open contact fire alarm and
supervisory devices.
The M210EA has a single tri-colour green/red/yellow LED, which can be set by panel
command to pulse green each time the module is polled. In case of an alarm the
panel can switch the red indicator on continuously. The Yellow LED is controlled by the
module and blinks to indicate an open circuit on the input circuit. This fault indication
is overridden by a panel command to turn the red LED on.
M220EA DUAL CHANNEL INPUT MODULE
This is a dual channel module used for the monitoring of normally open contact fire
alarm and supervisory devices.
It has two tri-colour LED's, one referring to each channel. Each LED can be set by
panel command to pulse green each time the module channel is polled. In case of
an alarm the panel can switch the red indicator on continuously. The Yellow LED is
controlled by the module and blinks to indicate an open circuit on the input circuit.
This fault indication is always overridden by a panel command to turn the red LED on.
M221EA DUAL INPUT, SINGLE OUTPUT MODULE
This module provides dual channel monitoring of normally open contact fire alarm
and supervisory devices, and also provides single pole changeover contacts for the
control of auxiliary devices such as fire shutters and sounders.
Three tri-colour LED's are provided to indicate the status of each channel.
LED's IN1 and IN2 refer to the two input channels. Each LED can be set by panel
command to pulse green each time the module channel is polled. In case of an alarm
the panel can switch the red indicator on continuously.
LED OUT refers to the output channel. The LED can be set by panel command to
pulse green each time the channel is polled. The LED will be switched continuously
on green by command from the control panel when the relay contacts are in the
energised state.
The M221EA relay contact ratings are 30VDC, 2A (Resistive load).
SPECIFICATIONS
Operating Voltage Range:
Maximum Standby Current:
LED Current (Red):
LED Current (Yellow):
Isolator features:
Humidity:
Maximum Wire Gauge
INSTALLATION
Note: These modules must only be connected to control panels using compatible
proprietary analogue addressable communication protocols for monitoring and control.
M200 series modules can be mounted in several ways (See Figure 1):
1:1 An M200E-SMB custom low profile surface-mounting box. The SMB Base is
affixed to mounting surface, and then the module and cover are screwed onto
the base using the two screws supplied. Box dimensions: 132 mm (H) x 137 mm
(W) x 40 mm (D)
1:2 The DIN bracket on top allows mounting onto standard 35 mm x 7.5 mm "Top Hat"
DIN rail inside a control panel or other suitable enclosure. Install and remove as
shown in Figure 1:2.
Wiring to all series M200 modules is via plug in type terminals capable of supporting
conductors up to 2.5 mm²
Disconnect loop power before installing modules or sensors.
The module address is selected by means of rotary decade address switches (see
Figure 4). A screwdriver should be used to rotate the wheels to select the desired
address, either from the front or the top of the module.
For modules having more than one channel, the address selected will refer to the first
(ii)
input channel, the module will automatically assign the next one or two addresses
as appropriate to the second input channel and output channel. As a result, address
159 will be invalid for dual channel modules, and addresses 158 and 159 are invalid
for three channel modules. If these addresses are selected, no response will be seen
from the module (not relevant if using Advanced Protocol - consult panel manufacturer
if in doubt).
Note: Some control panels are only able to use 99 addresses. If this is the case, 99
will be invalid for dual channel modules, and addresses 98 and 99 are invalid for three
channel modules.
15 to 32VDC (Min 16.5VDC for LED operation)
140 µA @24 V and 25
C (no communication)
o
1.5 mA
5.5 mA
see S00-7100
5% to 95% relative humidity (non-condensing)
2.5 mm²
CAUTION
I56-4400-001

Publicidad

loading

Resumen de contenidos para System Sensor M210EA

  • Página 1 Provides single channel monitoring of normally open contact fire alarm and supervisory devices. The M210EA has a single tri-colour green/red/yellow LED, which can be set by panel command to pulse green each time the module is polled. In case of an alarm the panel can switch the red indicator on continuously.
  • Página 2 Dispositivo sensibile alle scariche elettrostatiche Effettuare i collegamenti e maneggiare con cautela Il modello M210EA è dotato di un singolo LED tricolore (verde/rosso/giallo) che può essere impostato con un comando del pannello affinché lampeggi di luce verde ogniqualvolta il modulo viene interrogato. In caso di allarme, il pannello attiva Cablaggio M210EA / M220EA (ved.
  • Página 3 Tome las precauciones necesarias al manejar El M210EA tiene un solo LED de tres colores (verde/rojo/amarillo) que se puede el equipo y hacer las conexiones configurar desde el panel para que el led verde parpadee cada vez que se interrogue al módulo.
  • Página 4 Das Modul stellt einen Eingang zur Überwachung von Brandmeldekontakten mit Schliesserfunktion oder Überwachungskontakten zur Verfügung. Das M210EA besitzt eine 3-farbige grün/rot/gelb LED, die bei jeder Kommunikation ACHTUNG mit der Zentrale grün aufblinkt. Im Alarmfall kann von der Brandmelderzentrale zur Elektrostatisch empfindliches Gerat Beachten Sie die Vorschriften Anzeige die rote LED angesteuert werden.

Este manual también es adecuado para:

M220eaM221ea