WARNING:
TURN OFF THE PUMP AND UNPLUG THE POWER CORD BEFORE TROUBLESHOOTING THE FILTER PUMP.
SYMPTOM
A Unit not plugged in or
Motor fails to
1
start or kicks
B GFCI Plug and/or circuit
on and off
C Low voltage
A Low pool water level
No flow or slow
B Inlet/Outlet clogged
water flow through
2
the return hose.
C Dirty filter cartridge
A Chlorine level is not in
the suitable range.
B pH level is not in the
suitable range.
C Dirty filter cartridge
Filter pump is not
cleaning the pool
3
D Damaged filter cartridge
properly. (water
cloudy, green, etc...
E Slow water flow
F Other Chemicals Required
G Pool water very dirty
A Hose area:
Return hose do not fit well
on canister connections and/
or wall fitting connections
4
Water leakage
B Vent screw in Seal Top
C Seal Top
POOL PUMP DISASSEMBLY & STORAGE
1.
First turn off the pump and unplug the main power cord of the system. Now remove the RF Diverter Fitting
Return Fitting
with the RF P
25
Now thread the Water Cap
20
2. Slowly unscrew the Vent Screw
3. Remove the Seal Top Retainer
10
tablets left inside the core section of the filter.
4. Loosen all four Hose Clamps
14
5. Clean and dry all filter pump parts including filter cartridges.
6. Liberally lubricate the O-rings
22
Seal Top Retainer
, Vent Screw
10
7.
All items should be stored in a dry environment that remains above 32 degrees Fahrenheit at all times.
Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8 AM to 5 PM Mon. thru Fri.
14
TROUBLESHOOTING GUIDE
CAUSE
A Unit must be plugged into a 3-wire grounded power outlet. Press the reset button on the
GFCI not activated
B Reset the GFCI plug and/or circuit breaker. If problem persists, have the circuit
breaker tripped
C Check the line voltage, it must be in the range of 105 to 125 Volts A.C.
A Fill the pool to the fill line. The suction fitting must be at least 4" under water.
B Check for obstructions in the suction hose or fitting and in the return hose or fitting.
C Clean or replace the filter cartridge (See page 12). A spare cartridge makes service more
A Maintain chlorine level between 1.0 to 1.6 ppm.
B Maintain pH level between 7.3 to 7.8.
C Clean or replace the filter cartridge (See page 12). A spare cartridge makes service more
convenient
D Inspect the filter cartridge for holes or tears. If visibly damaged; replace the filter cartridge
E Check for obstructions in the suction hose or fitting and in the return hose or fitting.
F Have water tested at pool supply store. It may be necessary to add other chemicals due to
G Chemicals are required to maintain clean pool water. Clean pool and filter more often.
Suction or
A Make sure the hose clamp
to ensure a proper seal. Adjust hose clamp, check o-ring and re-tighten.
Check hose for any holes or cracks and replace if needed.
B Check O-ring
C Check O-ring
lug
.
21
onto the Suction Fitting
and hand tighten it only!
16
from the Seal Top
allowing the filter system to depressurize.
11
9
by turning counter-clockwise to unscrew. Remove the Seal Top
, remove the Suction and Return Hoses
, at the Seal Top
and
on the Vent Screw
9
23
onto the Filter Case
. Store all filter parts carefully.
11
8
MST. Extended operating days and hours during peak season requirements.
GFCI to start the pump.
checked by a qualified electrician.
convenient.
varying water quality in different localities.
is positioned properly over the hose and O-ring
14
for damage. Replace if needed. Tighten the Vent Screw
for damage. Replace if needed. Tighten the Seal Top
22
9
,
and allow water to drain out.
12 13
, with petroleum jelly, and then reassemble it along with the Seal Top
11
SOLUTION
from the Return Fitting (RF) and then plug the
28
. Remove the Filter Cartridge
and remove any chlorine
15
.
.
,
9

Publicidad