Keystone KSTAD507A El Manual Del Propietario página 14

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Removing the collected water
3. Pump draining (on some models)
Water can be automatically emptied into a floor
drain or a suitable drainage facility by attaching
the pump drain out with a pump drain hose
( od=1/4 , supplied).
Remove the continuous drain hose from the unit and install
the plastic cover to the continuous drain hose outlet of the
unit by clockwise rotation.(See Fig.11)
Resert the pump drain hose into the pump drain hose
outlet for depth of 15mm at least (See Fig.11), then lead
the water hose to the floor drain or a suitable drainage facility.
Press the pump pad of the unit to activated the pump
operation. When the bucket is full the pump starts to work.
NOTE: The pump may cause big noise when it starts to
work for 3~5 minutes. It is a normal phenomenon.
Make sure the hose is secure so there are no leaks.
Direct the hose toward the drain,making sure that there
are no kinks that will stop the warter flowing.
Place the end of the hose into the drain and make sure
the end of the hose is level or down to let the water flow
smoothly.Do never let it up.
Select the desired humidity setting and fan speed on the
unit for pump draining to start.
NOTE: The pump operation on light blinks at 1Hz when the
pump is operational failure. Please turn off the unit and plug
the power cord out. Check the following things:
Cleaning the filter of the pump.
-Remove the bucket from the unit, take down the pump
and clean the filter of the pump (See Fig.12).
Check that the pump drain hose does not link or block.
Empty the water of the bucket.
Reinstall the pump hose if it drops and reinstall the bucket
properly. Turn on the unit. If the error repeats, call for service.
NOTE: Do not use this operation when the outdoor temperature
is equal to or less than 0 C (32 F), otherwise water is become
ice that will cause the water hose blocked up and the unit failure.
Make sure to empty the bucket once a week when using
the pump draining feature. When the pump draining feature is
not being used, remove the pump drain hose from the outlet.
Press the pump drain hose outlet in and take the pump drain hose
out from it (See Fig.13). Make sure do not let the water in the pump
hose drip to the floor.
O
O
OPERATING THE UNIT
Reinstall the
plastic cover
2,Take the pump
drain hose out
9 9
Pump drain
hose outlet
Pump drain
hose
Fig.11
Filter of the pump
Fig.12
1,Press the pump drain
hose outlet in
Fig.13

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Kstad707a

Tabla de contenido