Installation Instructions - Lithonia Lighting TFX1 LED Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FIXTURE PACKING LIST
Description
1) LED Light Fixture ........................................................................................1
2) Mounting Plate & Gasket* ...........................................................................1
3) 1/2" 8-32 & 10-24 Mounting screws* ..........................................................4
4) Wire Nuts* ....................................................................................................3
*Contained in parts packs
Remove fi xture components and parts pack. Check to ensure all
parts are included. Note: Account for small parts and destroy packing
material, as these may be hazardous to children.
Turn OFF Power at circuit breaker box.
CAUTION: Do not rely on wall switch alone to turn off power.
THK - Threaded Knuckle Mounting:
For mounting to a wet location j-box, thread included mounting plate
onto knuckle and tighten locknut to secure or thread knuckle into a 1/2"
NPS hole in a compatible mounting apparatus. Note: Seal arm thread
using Tefl on tape or silicone sealant. Refer to wiring instructions for
power connection.
To adjust the tilt angle of the fi xture, use a 1/4" Allen wrench to loosen
the 5/16" socket head cap screw in the knuckle, rotate fi xture to the
desired angle and re-tighten screw to 7.2ft-lbs.
Locknut
YK - Yoke Mounting:
Mount fi xture to the desired bracketry with one 5/8" or two 1/2"
fasteners, lock washer, and nut (not provided). Tighten to 30ft-lbs. See
template of yoke bracket hole pattern below.
Quantity
socket head cap screw
Mounting Plate

INSTALLATION INSTRUCTIONS

The Yoke Mount option is provided with 2.6ft long 18AWG power
supply cord. A UL LISTED water tight cord connector suitable for use
with wet location fl exible cord shall be required in order to install onto a
wet location outdoor junction box. See image below.
To reduce risk of water entry when installing onto an outdoor junction
box ensure that a Tefl on tape or silicone sealant is applied on the
threaded portion of the fi tting. It is recommended that the water tight
cord connector be installed so that power supply cord exits towards the
ground. If existing wiring does not allow for installation of wires exiting
towards the ground, the use of an elbow suitable for wet location use
is recommended so that cord can exit towards the ground. See images
below.
To adjust the tilt angel of the fi xture, loosen the 1/4" hex head screw on
both sides of the yoke, adjust to desired angle and re-tighten screws to
secure.
1hex head screw
CAUTION: WIRING AND FIXTURE OPERATION
Make sure power is turned off .
To Ground fi xture use Wire Nut to connect the (copper) house supply
ground wire & the (green) fi xture ground wire. Note: If house wiring
does not include a ground wire, consult your local electrical code for
approved grounding methods.
For proper connection, place wire nut over
wires and twist clockwise until tight.
To connect supply wires use Wire Nuts to connect the black fi xture wire
to the black power supply wire and the white fi xture wire to the white
(neutral) supply wire.