Preparation
Installation instructions
•
Flexible conduit from the oven should be connected directly to the junction
box.
Fuse both sides of the line.
•
•
Do not cut the conduit. The length of conduit provided is for serviceability of
the oven.
•
A UL listed or CSA approved conduit connector must be provided.
•
If the house has aluminum wiring, follow the procedure below:
1.
Connect a section of solid copper wire to the ends of the flexible conduit
leads.
Connect the aluminum wiring to the added section of copper wire using
2.
special connectors and/or tools designed and UL listed for joining copper
to aluminum.
Follow the electrical connector manufacturer's recommended procedure.
Aluminum/copper connection must conform with local codes and industry
accepted wiring practices.
For power requirements for models NV51K6650D, NV51K6650S, NV51K7770D,
NV51K7770S, NV51R5511D, and NV51R5511S, refer to the following table.
Model
NV51K6650D
NV51K6650S
NV51K7770D
NV51K7770S
NV51R5511D
NV51R5511S
10 English
Install_NW9000K_DG68-00862A-07_EN.indd 10
240 VAC
208 VAC
kW
kW
9.3
7.0
4.9
3.7
10.6
8.0
6.2
4.7
8.9
6.7
4.5
3.4
Installation instructions
Prepare built-in oven
WARNING
Excessive Weight Hazard
Use two or more people to move and install an oven.
Failure to do so can result in back or other injury.
1.
Decide on the final location for the oven. Avoid drilling or cutting into house
wiring during installation.
To avoid floor damage, set the oven on a cardboard prior to installation. Do
2.
not use handle or any portion of the front frame for lifting.
3.
Remove the shipping materials and tape from the oven.
Remember to keep the packing materials that may be needed for installation.
4.
Remove the hardware package from inside of the bag containing literature.
5.
Remove racks and other parts from inside the oven.
6.
Move oven and cardboard close to the oven's final location.
2019-02-08