Installation Instructions for
CSS Series Shock / Vibration Switch
Please read the following instructions before installing. A visual inspection of this product for damage
during shipping is recommended before mounting. It is your responsibility to have a qualified person
install the unit and make sure installation conforms with local codes.
BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT
ü ü
Disconnect all electrical power to the machine.
ü ü
Disable operation of the machine during installation.
ü ü
Follow all safety recommendations of the machine manufacturer.
ü ü
Read and follow the installation instructions.
Description
The Murphy shock and vibration switches are available in a variety of models for applications on
machinery or equipment where excessive vibration or shock can damage the equipment or otherwise
poses a threat to safe operation. A set of contacts is held in a latched position through a mechanical
latch and magnet mechanism. As the level of vibration or shock increases an inertia mass exerts
force against the latch arm and forces it away from the magnetic latch causing the latch arm to
operate the contacts. Sensitivity is obtained by adjusting the gap between the magnet and the latch
arm plate.
Applications include all types of rotating or reciprocating machinery such as cooling fans, engines,
pumps, compressors, pump jacks etc.
Warranty
A two year limited warranty on materials and workmanship is provided with this Murphy product.
Details are available on request and are packed with each unit.
CSS Series
•
CSS Case
•
CSS Mounting
•
Electrical Connection
•
Contact rating
•
Sensitivity Range
•
Certification Body
•
Standard
•
Execution
3
GENERAL INFORMATION
Ü Ü WARNING Û Û
SPECIFICATIONS
Copperfree Cast Alloy (IP 55)
2 Hole bolt pattern
M20 x 1.5
Rating 5A @ 480 VAC or 2A resistive, 1A inductive, up to 30VDC
Manual reset models 2 SPDT micro-switches
Remote reset models 1 SPDT micro-switch
0 to 7 g (Depending on mounting position)
INIEX
EN 50014 / 50018 Cenelec
EEx-d-IIC-T6
1032X4LN
Revised 05-99
Section 20
YI5152