ENGLISH
EN
1.5 % 750,000cf
TWA (OSHA Method)
Based on the CO production rates shown above the TWA would not be exceeded in a
100 x 750 x 10 foot (empty) space after 8 hours with 2 air changes per hour.
exposure during 8 hour time period)
Maintenance of Equipment
Warning: The proper maintenance of equipment is vital to safe operation. LPG engines are dependent on
engine tune up, and air filter replacement. CO concentration (production) skyrockets when the air to fuel ratio becomes
fuel rich. Follow the recommended Maintenance Schedule for the engine found in the Engine Operator/Owner Manual as
well as the Maintenance And Adjustments schedule found in the Propane Floor Equipment Operator's Manual that were
supplied with the equipment.
CO Safety Equipment Available
•
Carb Guard automated emissions monitoring will shut down the engine when high emissions are detected.
•
Three-way type catalytic converter to scrub CO, Hydro Carbons (HC), and Nitrous Oxide (NOx) from the engine
exhaust providing the lowest possible emissions
•
High cubic feet per minute (CFM) fans (forced air mixing)
•
Digital combustion analyzers for tail pipe emissions monitoring
SPECIFICATIONS:
Model
Part Number
Brush Size
Engine
Catalytic Muffler
Carb Gard
Clutch
Brush Speed
Propane Tank
Auto Fuel Shutoff
Low Oil Shutdown
Hour Meter
Sound Level
Agency Approvals
CARB Certified
(California Air Resource Board)
Weight
Dimensions:
Length
Widith
Height
Warranty
- 10 - FORM NO. 71506A
8 Hour Time Weighted Average (OSHA Method)
Hours Operation
0 change/hr
1/2 change/hr
1 change/hr
2 change/hr
2113 BCATCLCG ST
08006B
21" (53 cm)
13 hp V-Twin Kawasaki
Yes
Yes
Centrifugal
1400 RPM
20 lb. (9.1 kg) Capacity, 80% Safety fill
Yes
Yes
Yes
88 - 90 dB(A)
EPA plus UL Approved Propane Components
Yes
51.5" (131.8 cm)
23.3" (59 cm)
43" (109.2 cm)
2 Years Parts & Labor
1
2
3
4
5
5
14
27
46
69
4
9
16
24
33
3
7
11
16
20
2
4
7
9
11
(Assumes no additional CO
PBU
Operator's Manual (EN) -
6
7
8
96
128 164
42
50
59
25
29
34
13
16
18
Propane Stripper