THE MACHINE MUST BE SWITCHED OFF AND LOCKED AND TAGGED PRIOR TO
SERVICING (ELECTRIC AND PNEUMATIC POWER SOURCES DISCONNECTED)
The following tools should be available at hand:
- Phillips and flat-blade screwdrivers
- Set of open-ended spanners and box spanners
- Set of Allen keys
- Multimeter
a� Replacing worn parts
- Silicone foam pads
Check that the platen is cold.
Make sure the surface of the platen is clean.
The surface can be cleaned using soapy water. Suitable personal protective
equipment must be worn.
Use RTV-1 glue to stick the foam pad to the aluminium platen (NB: read the
instructions for use on the packet).
The pad and the platen must be clean and dry before they are stuck together.
Apply a thin layer of glue evenly over the platen and then stick the pad
immediately into place, making sure there are no air bubbles trapped between
the platen and the pad (e.g. a notched tile adhesive comb).
Leave to set overnight at room temperature with a slight pressure applied and
the platen cold.
- For other parts, contact your stockist to determine whether they need to be renewed
or repaired.
b� Maintenance
SEFA heat presses are practically maintenance-free. Follow the preventive mainte-
nance instructions below to ensure trouble-free operation:
Do not heat items that could perish or score the silicone pad or damage the heat
platen's teflon coating.
Clean the machine at regular intervals, with the platen cold, using a clean cloth and
soapy water and wearing suitable personal protective equipment.
Keep the heat platen in the raised position when it is hot but not in use.
DAILY CARE:
Clean the foam pad and the heat platen's coating (when cold) with a dry cloth
or a cloth with grease remover.
Inspect the air inlet filter on the left side of the swing arm; drain the filter if it is
heavily condensated.
MONTHLY CARE:
Check that the hinged joints are lubricated.
According to use:
Replace the foam pad every 6 months.
www.sefa.fr
SERVICING
TO BE PERFORMED BY QUALIFIED PERSONNEL
User guide - SEFA CLAM SPORT V3
15