GE JGRS14 Instructions De Instalacion página 7

Horno a gas empotrado de 24”
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAKE THE L.P. GAS CONVERSION
WARNING:
(bottled) gas all the adjustments described
below must be made before you make any
burner adjustments or use the oven.
WARNING:
be performed by a qualified installer or gas
supplier in accordance with the
manufacturer's instructions and all codes
and requirements of the authority having
jurisdiction. Failure to follow instructions
could result in serious injury or property
damage. The qualified agency performing
this work assumes responsibility for the
conversion.
NOTE: Disconnect all electrical power and turn
off the gas supply at the shut-off valve before
beginning the conversion.
1
ADJUST PRESSURE
REGULATOR FROM NATURAL
GAS TO L.P.
Locate and remove regulator cover and wire
A
clip.
Pressure
Adaptor
Regulator
Remove Regulator Cover
Locate the regulator and unscrew the cap.
B
Gasket
NAT.
NAT.
C
Turn the retainer over so L.P. is showing on
the bottom of the retainer.
Replace the cap.
D
Replace the regulator cover.
E
Installation Instructions
If you are using L.P.
This conversion must
Flexible Connection
Remove
Wire Clip
Cap
Spring
Retainer
L.P.
l..P.
ADJUST BURNER ORIFICE
2
FROM NATURAL TO L.P. GAS
CAUTION:
next column must be made before turning
on the burners. Failure to do so could result
in serious injury due to high flames and
toxic fumes.
Open the oven door.
A
Remove the oven bottom.
B
Remove the oven baffle (flame spreader).
C
Oven Bottom
Burner Baffle
ADJUST OVEN BURNER
3
Use a 1/2" open end or adjustable wrench to turn
the orifice hood in the L.P. direction, about 1 1/2
turns, until snug.
NAT.
Air Shutter
NAT. – L.P.
Adjustment
Made To Orifice Hood
IMPORTANT: Do not overtighten or you may
bend the orifice hood or needle.
CHECK FLAME SIZE
4
Check the inner cone of
the flame. It should be
approximately 1/2" to 3/4"
long for the oven and
broil burners.
If the flame size is too
long, use a 1/2" open end
wrench or adjustable joint
pliers to adjust the orifice
hood, by turning in the natural direction.
WARNING:
measure the inner cone of the flame,
please use caution; burns could result.
7
The adjustments in the
L.P.
1/2"
to 3/4"
Inner Cone
of Flame
If you attempt to

Publicidad

Tabla de contenido
loading

Tabla de contenido