Dyna-Glo BFSS10LPT-2P Manual De Instrucciones página 19

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
THERMOSTAT GAS CONTROL
1. STOP! Read the safety information on the previous page.
2. Turn off all electric power to the appliance.
3. Turn control knob clockwise
4. Wait (5) minutes to clear out any gas. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow "B" in the safety
information above. If you don't smell gas, go to the next step.
5. Turn knob counterclockwise
(See Fig. 23b) Depress control knob.
6. With control knob depressed, push down on the ignitor button
until the pilot lights. The pilot is visible centered below the
plaques, behind the front grill. (See Fig. 24)
7. Keep control depressed for (30) seconds after pilot lights. Release
control knob.
Note: If pilot goes out repeat steps 3 through 7. Wait (1) minute before
attempting to light pilot again. If after several tries the pilot still goes out,
turn the gas control knob clockwise
your service technician or gas supplier. If the control knob does not pop up
when released, stop and immediately and call your service technician or
gas supplier.
8. Turn on all electric power to the appliance.
9. Turn control knob counter clockwise
1. Turn off all electric power to the appliance if service is to be performed.
2. Push in gas control knob slightly and turn clockwise
DO NOT FORCE.
LIGHTING INSTRUCTIONS
to "OFF" position. (See Fig. 22b)
to the "PILOT" position.
to the "OFF" position and call
to desired setting.
TO TURN OFF GAS TO APPLIANCE
18
Fig. 24 - Pilot Flame Location
Pilot Flame Location
to "OFF" or "
" position.
Fig. 22b
Fig. 23b

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Bfss20lpt-2pBfss30lpt-2pBfss10ngt-2nBfss20ngt-2nBfss30ngt-2n

Tabla de contenido