AL 9
-Appears when the
INSUFF
combustion air flow is
below a certain threshold.
DRAUGHT
-Occurs when the
AL b
gearmotor works
AUG TRIAC
continuously and for more
than 60 sec.
ERROR
-The system is stopped.
-Occurs on relighting the
WAITING
stove immediately after
COOL
having shut it down.
AIR FLOW
-Occurs when the air flow
METER
meter is disconnected.
FAILURE
- Occurs when the stove
has exceeded 1800 hours
SERVICE
of operation or 2000 Kg
DUE
pellet, since the previous
servicing.
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
-The combustion chamber is
dirty.
-The fume duct is obstructed.
-The fire door is not closed.
-The overpressure valves are
open-stuck.
-Faulty air flow meter.
-The controller
faulty
relay (contacts stuck).
-Reset attempt in shutdown
stage with stove hot in
cooling stage.
-The controller does not
detect the quantity of
combustion air and does not
shut down the stove; it only
excludes the air flow meter
functions.
-Extraordinary
notice.
"direzione e coordinamento della Ferroli spa"
62
-Check cleanness of the fume duct
and combustion chamber.
-Check hermetic closing of the
door.
-Check closing of the overpressure
valves.
-Other reinstatement operations
must be carried out by a service
centre.
detects
a
-Reinstatement operations must be
gearmotor
control
carried out by a service centre.
-Alarm reset is possible only after
shutdown.
-Reinstatement operations must be
carried out by a service centre.
- Cleaning - extraordinary
maintenance and reinstatement
maintenance
operations must be carried out by a
authorised service centre.
BEAUTY 13