Panasonic WH-MXC16G9E8 Manual De Instalación página 6

Bomba de calor aire-agua (mono bloc)
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
Terminals on the Mono bloc unit
Lead wire cord
Terminal
Tightening torque
N•cm {kgf•cm}
screw
M4
157~196 {16~20}
M5
196~245 {20~25}
Tank Sensor Resistant Vs Temperature
16000
14000
12000
10000
8000
6000
4000
2000
0
-30 -20 -10
Graph 4.1: Tank sensor characteristic
CONNECTING REQUIREMENT
The equipment's power supply 1 complies with IEC/EN 61000-3-2.
The equipment's power supply 1 complies with IEC/EN 61000-3-3 and can be connected to current supply network.
The equipment's power supply 2 complies with IEC/EN 61000-3-2.
The equipment's power supply 2 complies with IEC/EN 61000-3-3 and can be connected to current supply network.
WIRED REMOTE CONTROL 3 INSTALLATION
Do not modify the length of the remote control cable. Otherwise, it will cause fi re or electrical shock.
Be sure to turn off the main power before installing and connecting the remote control. Otherwise, it will cause the electrical shock.
Use the attached accessories parts and specifi ed parts for installation. Otherwise, it will cause the set to fall, fi re or electrical shock.
Wire routing must be properly arranged so that control board cover is fi xed properly. If control board cover is not fi xed properly, it will cause fi re
or electrical shock.
If passing the remote control cable through a wall, be sure to install a water trap above the cable. Otherwise, it will cause the electrical shock.
Install in a fl at surface to avoid warping of remote control, else damage to the LCD case or operation problems may result.
Avoid installing the remote control cable near refrigerant pipes or water pipes, else will cause electrical shock or fi re.
Install the remote control cable at least 5cm away from electric wires of other appliances to avoid miss operation (electromagnetic noise).
Be sure to use only the accessory screws to avoid damage of remote control PCB.
6
1
2
3
4
5
6
Two-way
Three-way
Valve Cable
Valve Cable
WIRE STRIPPING AND CONNECTING REQUIREMENT
Wire stripping
No loose strand when
insert
Remove this
jumper if External
Controller (Optional)
is connected to the
Mono bloc unit
0
10
20
30
˚C
Diagram 4.2: External Controller connecting diagram
7
8
9 10 11 12
Tank OLP
Booster Heater
Room Thermostat
Cord
Cable
Terminal
board
5 mm or
more
(gap between
wires)
External Controller
Terminal
Switch (ON/OFF)
17
18
WARNING
CAUTION
13 14 15 16 17 18
19 20 21
Tank
External
Solar Three- way
Cable
Sensor
Controller
Valve Cable
Cable
Cable
Only if Solar Connection PCB installed
Conductor
Conductor over
Conductor not fully
fully insert
insert
ACCEPT
PROHIBITED
PROHIBITED
22 23
Solar Pump
Station Cable
insert

Publicidad

Tabla de contenido
loading

Tabla de contenido